Performance Analysis of a Solar-Assisted Air Source Heat Pump with Cascaded Latent Heat Storage and Utilization for Building Heating

The solar-assisted air source heat pump (SAHP) is a key technology of low carbon heating. However, the SAHP is still inefficient and unstable at low temperatures. Cascaded latent heat storage (CLHS) can store multi-stage thermal energy, which provides the possibility for the multiple utilization of solar energy. Hence, this paper proposed the SAHP integrated with CLHS for building heating. The high-temperature and medium-temperature latent heat storage (LHS) units are used for direct heating, and the low-temperature LHS unit preheats the air for the air source heat pump (ASHP). The thermal performance of the CLHS device is evaluated through combined numerical simulations and experimental tests. Results show that the average heat storage rate of the cascaded system is 61.1% higher than that of a conventional single-stage LHS unit. The heat storage uniformity of CLHS gradually improves with increasing inlet flow rate, but shows a trend of first increasing and then decreasing with the increase in fluid inlet temperature. Among the three tested levels, 80 °C was found to be the most uniform heat storage of the CLHS device. The performance of the system was further analyzed using TRNSYS to assess seasonal building heating performance. The overall efficiencies of the high/middle/low temperature LHS units are 93.6%, 81.6% and 94.3%, respectively. And the solar heat supply accounts for 70.8% of the total heat supply of the system. Compared with the non-preheating system where the low-temperature LHS unit is removed, the COP of the graded heating system is increased by 18.3%, and the energy consumption is reduced by 16.6%. Further parametric optimization based on the Hooke–Jeeves method reduces total system energy consumption by 20.7% and associated pollutant emissions by 20.6% compared with the pre-optimization system. The findings provide practical insights into the application of CLHS in solar-assisted heat pump systems for building heating.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2026-04-14
DOI
https://doi.org/10.3390/buildings16081541
Primary Topic
Geothermal Energy Systems and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Analysis of a Solar-Assisted Air Source Heat Pump with Cascaded Latent Heat Storage and Utilization for Building Heating

Lu Wang, Xiangfei Kong, Jiale Chai, Bowen Xu et al.
Buildings
Geothermal Energy Systems and Applications
article

Performance Analysis of a Solar-Assisted Air Source Heat Pump with Cascaded Latent Heat Storage and Utilization for Building Heating

Lu Wang, Xiangfei Kong, Jiale Chai, Bowen Xu, Yuliang Zhong, Yimeng Sun
article en

Abstract

The solar-assisted air source heat pump (SAHP) is a key technology of low carbon heating. However, the SAHP is still inefficient and unstable at low temperatures. Cascaded latent heat storage (CLHS) can store multi-stage thermal energy, which provides the possibility for the multiple utilization of solar energy. Hence, this paper proposed the SAHP integrated with CLHS for building heating. The high-temperature and medium-temperature latent heat storage (LHS) units are used for direct heating, and the low-temperature LHS unit preheats the air for the air source heat pump (ASHP). The thermal performance of the CLHS device is evaluated through combined numerical simulations and experimental tests. Results show that the average heat storage rate of the cascaded system is 61.1% higher than that of a conventional single-stage LHS unit. The heat storage uniformity of CLHS gradually improves with increasing inlet flow rate, but shows a trend of first increasing and then decreasing with the increase in fluid inlet temperature. Among the three tested levels, 80 °C was found to be the most uniform heat storage of the CLHS device. The performance of the system was further analyzed using TRNSYS to assess seasonal building heating performance. The overall efficiencies of the high/middle/low temperature LHS units are 93.6%, 81.6% and 94.3%, respectively. And the solar heat supply accounts for 70.8% of the total heat supply of the system. Compared with the non-preheating system where the low-temperature LHS unit is removed, the COP of the graded heating system is increased by 18.3%, and the energy consumption is reduced by 16.6%. Further parametric optimization based on the Hooke–Jeeves method reduces total system energy consumption by 20.7% and associated pollutant emissions by 20.6% compared with the pre-optimization system. The findings provide practical insights into the application of CLHS in solar-assisted heat pump systems for building heating.

BuildingsVol. 16(8)
Hebei University of Technology (CN), Hebei University of Environmental Engineering (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 31%
Geothermal Energy Systems and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.