Synthesis of PLA coating on ZK41 Mg alloy for improved biodegradation resistance as an implant material

Magnesium (Mg) alloys are promising biodegradable biomaterials for implant applications due to their biodegradability, biocompatibility, and mechanical properties like those of natural bone tissue. Despite favourable properties, Mg alloys are rarely used as biodegradable implants because they corrode rapidly in physiological environments. This study employed dip-coated polylactic acid (PLA)-apatite polymer coatings on ZK41 Mg alloy to improve the system's integrity. The coating solutions were prepared using PLA with chloroform, dichloromethane, and a combination of both solvents to prevent degradation of the ZK41 alloy. Surface characteristics of the samples were examined using scanning electron microscopy (SEM), Fourier-transform infrared spectroscopy (FTIR), Rockwell hardness testing, and pH measurements. Results indicated that a compact, uniform PLA coating on ZK41 alloy could be achieved using a mixture of chloroform and dichloromethane. A hardness measurement of this sample showed better mechanical properties than the other samples. Additionally, in vitro biodegradation performance was assessed through immersion tests and tests in Hank's solution (HBSS) at 37 °C. The ZK41 alloy coated with PLA using chloroform and dichloromethane, with 25% higher hardness than pure ZK41 alloy, exhibited the highest adhesion strength and degradation resistance compared to the uncoated and coated with PLA + chloroform or PLA + dichloromethane samples. The uncoated ZK41 Mg alloy exhibited the highest degradation rate of 25.2 ± 1.44 mg/cm 2 after 14 days, whereas the PLA-coated sample with chloroform and dichloromethane showed the lowest rate at 7.32 ± 0.12 mg/cm 2 . This sample also shows the lowest evolution of H 2 gas after 24 hr immersion period. • PLA coatings on ZK41 Mg alloy were synthesized and characterized using Chloroform and Dichloromethane (DCM) solvents. • Mechanical properties, like the hardness of the PLA-coated alloy, improved with the use of mixed solvents. • The incorporation of PLA coating with mixed solvents on the ZK41 Mg alloy enhanced the in vitro biodegradation resistance.

Authors

Institutions

Publication Details

Journal
Results in Surfaces and Interfaces
Published
2026-04-14
DOI
https://doi.org/10.1016/j.rsurfi.2026.100809
Primary Topic
Magnesium Alloys: Properties and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Synthesis of PLA coating on ZK41 Mg alloy for improved biodegradation resistance as an implant material

Md. Ramjan Ali, Mostafizur Rahman, Robiul Alam, Md Osman Ali et al.
Results in Surfaces and Interfaces
Magnesium Alloys: Properties and Applications
article

Synthesis of PLA coating on ZK41 Mg alloy for improved biodegradation resistance as an implant material

Md. Ramjan Ali, Mostafizur Rahman, Robiul Alam, Md Osman Ali, Saifullah Mahmud, Sajib Kumar Nath, Hazera Khatun, Ekramul Islam
article en

Abstract

Magnesium (Mg) alloys are promising biodegradable biomaterials for implant applications due to their biodegradability, biocompatibility, and mechanical properties like those of natural bone tissue. Despite favourable properties, Mg alloys are rarely used as biodegradable implants because they corrode rapidly in physiological environments. This study employed dip-coated polylactic acid (PLA)-apatite polymer coatings on ZK41 Mg alloy to improve the system's integrity. The coating solutions were prepared using PLA with chloroform, dichloromethane, and a combination of both solvents to prevent degradation of the ZK41 alloy. Surface characteristics of the samples were examined using scanning electron microscopy (SEM), Fourier-transform infrared spectroscopy (FTIR), Rockwell hardness testing, and pH measurements. Results indicated that a compact, uniform PLA coating on ZK41 alloy could be achieved using a mixture of chloroform and dichloromethane. A hardness measurement of this sample showed better mechanical properties than the other samples. Additionally, in vitro biodegradation performance was assessed through immersion tests and tests in Hank's solution (HBSS) at 37 °C. The ZK41 alloy coated with PLA using chloroform and dichloromethane, with 25% higher hardness than pure ZK41 alloy, exhibited the highest adhesion strength and degradation resistance compared to the uncoated and coated with PLA + chloroform or PLA + dichloromethane samples. The uncoated ZK41 Mg alloy exhibited the highest degradation rate of 25.2 ± 1.44 mg/cm 2 after 14 days, whereas the PLA-coated sample with chloroform and dichloromethane showed the lowest rate at 7.32 ± 0.12 mg/cm 2 . This sample also shows the lowest evolution of H 2 gas after 24 hr immersion period. • PLA coatings on ZK41 Mg alloy were synthesized and characterized using Chloroform and Dichloromethane (DCM) solvents. • Mechanical properties, like the hardness of the PLA-coated alloy, improved with the use of mixed solvents. • The incorporation of PLA coating with mixed solvents on the ZK41 Mg alloy enhanced the in vitro biodegradation resistance.

Results in Surfaces and InterfacesVol. 23
Dhaka University of Engineering & Technology (BD)
Openalex Percentile: Top 21%
Magnesium Alloys: Properties and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.