Indoor Air Filtration System Performance: Evidence from a Two-Week Office Study Within the EDIAQI Project

This two-week pilot study within the Horizon Europe EDIAQI project evaluated the real-life performance of portable air filtration units in two office environments (a small office and a shared kitchen) under continuous device operation and daily filter replacement. Indoor particle concentrations were monitored continuously using low-cost sensors (LCS) from three providers and supported by gravimetric measurements, while daily activity logs documented occupancy patterns, printing, cooking, and other source events together with purifier ON/OFF status. Particulate matter (PM) mass concentrations showed no systematic improvement during purifier ON periods; instead, temporal variability was dominated by indoor activities and episodic emissions, with occasional short-term peaks around filter replacement suggestive of minor resuspension. Chemical analysis provided a clearer picture: polycyclic aromatic hydrocarbons (PAHs) responded differently across fractions and compositions. Across monitored locations, high-molecular-weight PAHs in the PM1 fraction decreased during purifier ON periods (approximately 30% lower on average), whereas low-molecular-weight PAHs measured in total suspended particles (TSP) were higher during ON periods, indicating that semi-volatile fractions and activity/ventilation dynamics can outweigh simple filtration effects. Overall, the findings highlight a gap between laboratory-derived filtration performance metrics and outcomes in occupied, mixed-source indoor environments and emphasise the importance of device sizing, placement, airflow mixing, and complementary source control and ventilation strategies when deploying filtration-based IAQ interventions.

Authors

Institutions

Publication Details

Journal
Atmosphere
Published
2026-04-14
DOI
https://doi.org/10.3390/atmos17040393
Primary Topic
Aerosol Filtration and Electrostatic Precipitation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Indoor Air Filtration System Performance: Evidence from a Two-Week Office Study Within the EDIAQI Project

Francesco Mureddu, Gordana Pehnec, Goran Gajski, Mario Lovrić et al.
Atmosphere
Aerosol Filtration and Electrostatic Precipitation
article

Indoor Air Filtration System Performance: Evidence from a Two-Week Office Study Within the EDIAQI Project

Francesco Mureddu, Gordana Pehnec, Goran Gajski, Mario Lovrić, Ivana Jakovljević, Valentino Petrić, Marija Jelena Lovrić Štefiček, Nikolina Račić
article en

Abstract

This two-week pilot study within the Horizon Europe EDIAQI project evaluated the real-life performance of portable air filtration units in two office environments (a small office and a shared kitchen) under continuous device operation and daily filter replacement. Indoor particle concentrations were monitored continuously using low-cost sensors (LCS) from three providers and supported by gravimetric measurements, while daily activity logs documented occupancy patterns, printing, cooking, and other source events together with purifier ON/OFF status. Particulate matter (PM) mass concentrations showed no systematic improvement during purifier ON periods; instead, temporal variability was dominated by indoor activities and episodic emissions, with occasional short-term peaks around filter replacement suggestive of minor resuspension. Chemical analysis provided a clearer picture: polycyclic aromatic hydrocarbons (PAHs) responded differently across fractions and compositions. Across monitored locations, high-molecular-weight PAHs in the PM1 fraction decreased during purifier ON periods (approximately 30% lower on average), whereas low-molecular-weight PAHs measured in total suspended particles (TSP) were higher during ON periods, indicating that semi-volatile fractions and activity/ventilation dynamics can outweigh simple filtration effects. Overall, the findings highlight a gap between laboratory-derived filtration performance metrics and outcomes in occupied, mixed-source indoor environments and emphasise the importance of device sizing, placement, airflow mixing, and complementary source control and ventilation strategies when deploying filtration-based IAQ interventions.

AtmosphereVol. 17(4)
University of Zagreb (HR), Institute for Anthropological Research (HR), Institute for Medical Research and Occupational Health (HR), University of Osijek (HR)
HORIZON EUROPE Framework Programme, NextGenerationEU
Responsible consumption and production
Openalex Percentile: Top 24%
Aerosol Filtration and Electrostatic Precipitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.