Feasibility, agreement, and time savings of PHANTOM open-field binocular integrated refraction versus conventional clinical refraction in healthy young adults

PHANTOM is a novel open-field binocular integrated refraction system that uses device-specific binocular target presentation and lensless refractive simulation to perform objective refraction, subjective refraction, and visual acuity testing in one device. However, evidence is limited regarding how corrective refraction derived from such systems compares with prescriptions obtained using conventional subjective refraction combined with binocular balancing. We aimed to compare refractive correction determined using the conventional method with that obtained using PHANTOM and evaluate its potential role as an adjunctive tool for spectacle prescription. We compared PHANTOM with a conventional clinical refraction workflow. Twenty healthy young adults (20.3 ± 0.9 years) were subjected to both conditions in a randomized order, with examinations performed by one experienced orthoptist; right eye data were analyzed. Conventional refraction comprised monocular autorefraction plus subjective refraction with prism-dissociated duochrome binocular balancing. Agreement (PHANTOM–conventional) was assessed using the Bland–Altman analysis. Objective spherical equivalent (SE) was − 3.09 ± 2.25 D vs. −3.10 ± 2.24 D (bias 0.02 D; 95% limits of agreement [LoA] − 0.55 to 0.58). Subjective SE was − 2.78 ± 2.41 D vs. −2.79 ± 2.39 D (bias 0.01 D; LoA − 0.56 to 0.58) with no proportional bias. Proportional bias was detected in objective J45 (p = 0.01) and subjective J0 (p = 0.006). Visual acuity was − 0.17 ± 0.02 vs. −0.16 ± 0.04 logMAR (bias − 0.01; LoA − 0.10 to 0.08). Examination time was 199.7 ± 33.9 vs. 527.6 ± 70.0 s (61.6% shorter; p < 0.0001). In healthy young adults under controlled study conditions, participants completed the integrated PHANTOM protocol and achieved visual-acuity endpoints comparable to those obtained with conventional refraction. Under these conditions, SE agreement was generally good and the examination time was substantially reduced, whereas astigmatism components warrant further investigation. Further validation in broader clinical populations is required before these findings can be generalized.

Authors

Institutions

Publication Details

Journal
BMC Ophthalmology
Published
2026-04-14
DOI
https://doi.org/10.1186/s12886-026-04825-6
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility, agreement, and time savings of PHANTOM open-field binocular integrated refraction versus conventional clinical refraction in healthy young adults

Tomoya Handa, Takushi Kawamorita, Yo Iwata, Rie Hoshikawa
BMC Ophthalmology
Ophthalmology and Visual Impairment Studies
article

Feasibility, agreement, and time savings of PHANTOM open-field binocular integrated refraction versus conventional clinical refraction in healthy young adults

Tomoya Handa, Takushi Kawamorita, Yo Iwata, Rie Hoshikawa
article en

Abstract

PHANTOM is a novel open-field binocular integrated refraction system that uses device-specific binocular target presentation and lensless refractive simulation to perform objective refraction, subjective refraction, and visual acuity testing in one device. However, evidence is limited regarding how corrective refraction derived from such systems compares with prescriptions obtained using conventional subjective refraction combined with binocular balancing. We aimed to compare refractive correction determined using the conventional method with that obtained using PHANTOM and evaluate its potential role as an adjunctive tool for spectacle prescription. We compared PHANTOM with a conventional clinical refraction workflow. Twenty healthy young adults (20.3 ± 0.9 years) were subjected to both conditions in a randomized order, with examinations performed by one experienced orthoptist; right eye data were analyzed. Conventional refraction comprised monocular autorefraction plus subjective refraction with prism-dissociated duochrome binocular balancing. Agreement (PHANTOM–conventional) was assessed using the Bland–Altman analysis. Objective spherical equivalent (SE) was − 3.09 ± 2.25 D vs. −3.10 ± 2.24 D (bias 0.02 D; 95% limits of agreement [LoA] − 0.55 to 0.58). Subjective SE was − 2.78 ± 2.41 D vs. −2.79 ± 2.39 D (bias 0.01 D; LoA − 0.56 to 0.58) with no proportional bias. Proportional bias was detected in objective J45 (p = 0.01) and subjective J0 (p = 0.006). Visual acuity was − 0.17 ± 0.02 vs. −0.16 ± 0.04 logMAR (bias − 0.01; LoA − 0.10 to 0.08). Examination time was 199.7 ± 33.9 vs. 527.6 ± 70.0 s (61.6% shorter; p < 0.0001). In healthy young adults under controlled study conditions, participants completed the integrated PHANTOM protocol and achieved visual-acuity endpoints comparable to those obtained with conventional refraction. Under these conditions, SE agreement was generally good and the examination time was substantially reduced, whereas astigmatism components warrant further investigation. Further validation in broader clinical populations is required before these findings can be generalized.

BMC Ophthalmology
Kitasato University (JP)
Openalex Percentile: Top 22%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.