Thread Depth Effects on Stability and Positional Accuracy in Guided Immediate Implants: A Randomized Controlled Trial

OBJECTIVES: To evaluate the influence of implant thread depth on implant stability and positional accuracy in fully guided immediate implant placement. MATERIALS AND METHODS: Fifty-four patients received a reference tapered (BLT), a standard-thread (MST), or a deep-thread implant (MDT). Fifty-four implants were placed using fully guided surgery and evaluated over 1-year follow-up. Primary outcomes were implant stability (insertion torque, ISQ, ISV). Secondary outcomes included positional accuracy and marginal bone level (MBL) at 12 months. RESULTS: Primary and longitudinal stability were comparable across groups. Insertion torque was highest for MDT implants, followed by MST and BLT implants (BLT: 35.28 ± 11.18; MST: 40.00 ± 11.88; MDT: 43.89 ± 10.92 Ncm; p = 0.062). A higher proportion of MDT implants achieved insertion torque ≥ 40 Ncm (MDT: 14/18; MST: 12/18; BLT: 8/18). Angular deviation differed among implant groups (MDT: 5.57° ± 3.71°; BLT: 4.73° ± 2.46°; MST: 3.58° ± 1.81°; p = 0.062). In subgroup analysis comparing implants differing only in thread depth (MST vs. MDT), angular deviation was significantly greater for MDT (p = 0.029), particularly in molar sites. At 12 months, MBL did not differ significantly among groups. CONCLUSIONS: In fully guided immediate implant placement, deeper-thread implants showed higher insertion torque values but were associated with greater angular deviation, while longitudinal stability and marginal bone levels remained comparable. Deeper-thread designs may be beneficial when enhanced primary stability is required, provided careful angulation control is ensured. TRIAL REGISTRATION: cris.nih.go.kr Identifier: KCT0009402; This clinical trial was not registered prior to participant recruitment and randomization.

Authors

Institutions

Publication Details

Journal
Clinical Implant Dentistry and Related Research
Published
2026-04-01
DOI
https://doi.org/10.1111/cid.70145
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thread Depth Effects on Stability and Positional Accuracy in Guided Immediate Implants: A Randomized Controlled Trial

Franz Josef Strauß, Ji‐Young Jung, Jung‐Seok Lee, Seung‐Hyun Park et al.
Clinical Implant Dentistry and Related Research
Dental Implant Techniques and Outcomes
article

Thread Depth Effects on Stability and Positional Accuracy in Guided Immediate Implants: A Randomized Controlled Trial

Franz Josef Strauß, Ji‐Young Jung, Jung‐Seok Lee, Seung‐Hyun Park, Na‐Yoon Kwon, Kyung‐A Ko
article en

Abstract

OBJECTIVES: To evaluate the influence of implant thread depth on implant stability and positional accuracy in fully guided immediate implant placement. MATERIALS AND METHODS: Fifty-four patients received a reference tapered (BLT), a standard-thread (MST), or a deep-thread implant (MDT). Fifty-four implants were placed using fully guided surgery and evaluated over 1-year follow-up. Primary outcomes were implant stability (insertion torque, ISQ, ISV). Secondary outcomes included positional accuracy and marginal bone level (MBL) at 12 months. RESULTS: Primary and longitudinal stability were comparable across groups. Insertion torque was highest for MDT implants, followed by MST and BLT implants (BLT: 35.28 ± 11.18; MST: 40.00 ± 11.88; MDT: 43.89 ± 10.92 Ncm; p = 0.062). A higher proportion of MDT implants achieved insertion torque ≥ 40 Ncm (MDT: 14/18; MST: 12/18; BLT: 8/18). Angular deviation differed among implant groups (MDT: 5.57° ± 3.71°; BLT: 4.73° ± 2.46°; MST: 3.58° ± 1.81°; p = 0.062). In subgroup analysis comparing implants differing only in thread depth (MST vs. MDT), angular deviation was significantly greater for MDT (p = 0.029), particularly in molar sites. At 12 months, MBL did not differ significantly among groups. CONCLUSIONS: In fully guided immediate implant placement, deeper-thread implants showed higher insertion torque values but were associated with greater angular deviation, while longitudinal stability and marginal bone levels remained comparable. Deeper-thread designs may be beneficial when enhanced primary stability is required, provided careful angulation control is ensured. TRIAL REGISTRATION: cris.nih.go.kr Identifier: KCT0009402; This clinical trial was not registered prior to participant recruitment and randomization.

Clinical Implant Dentistry and Related ResearchVol. 28(2)
Yonsei University (KR), University of Zurich (CH), Universidad Autónoma de Chile (CL)
National Research Foundation, National Research Foundation of Korea, Ministry of Science and ICT, South Korea
Openalex Percentile: Top 15%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.