Single-Crystal 4π Time Scintillation Spectrometers of Delayed Coincidence

Two types of single-crystal time 4π spectrometers are considered, which are used the scintillators with a short decay time. These spectrometers allow searching for short lived excited and ground states of nuclei in the nano- and microsecond range. Single-crystal scintillation time spectrometry, which enables 4π detection of delayed coincidences, has been developed in two directions–using slow scintillators such as NaJ(Tl) [1] or plastic scintillators with a decay time in the nanosecond range [2]. The methods applied for detecting delayed coincidences were different: while in the former case, the fast-slow coincidence method with the measurement of level lifetimes in the microsecond range is employed, in the second case, it is the autocorrelation method, which allows the measurement of level lifetimes starting from the nanosecond range. The lower limit of the measured times in this range is determined by the duration of the scintillator decay pulse at the level of the integral discriminator response threshold and the dead time of the discriminator used.

Authors

Institutions

Publication Details

Journal
Physics of Particles and Nuclei Letters
Published
2026-04-01
DOI
https://doi.org/10.1134/s1547477125702140
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Single-Crystal 4π Time Scintillation Spectrometers of Delayed Coincidence

Н. В. Морозова, V. A. Morozov
Physics of Particles and Nuclei Letters
Radiation Detection and Scintillator Technologies
article

Single-Crystal 4π Time Scintillation Spectrometers of Delayed Coincidence

Н. В. Морозова, V. A. Morozov
article en

Abstract

Two types of single-crystal time 4π spectrometers are considered, which are used the scintillators with a short decay time. These spectrometers allow searching for short lived excited and ground states of nuclei in the nano- and microsecond range. Single-crystal scintillation time spectrometry, which enables 4π detection of delayed coincidences, has been developed in two directions–using slow scintillators such as NaJ(Tl) [1] or plastic scintillators with a decay time in the nanosecond range [2]. The methods applied for detecting delayed coincidences were different: while in the former case, the fast-slow coincidence method with the measurement of level lifetimes in the microsecond range is employed, in the second case, it is the autocorrelation method, which allows the measurement of level lifetimes starting from the nanosecond range. The lower limit of the measured times in this range is determined by the duration of the scintillator decay pulse at the level of the integral discriminator response threshold and the dead time of the discriminator used.

Physics of Particles and Nuclei LettersVol. 23(2)
Joint Institute for Nuclear Research (RU)
Openalex Percentile: Top 7%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.