Phase-based optoretinographic measurements of cones with a raster-scanning adaptive optics OCT are highly repeatable

Optoretinography (ORG) is a class of methods that use noninvasive, all-optical techniques to measure stimulus-evoked responses in the retina. By conveying functional and structural information at once, it offers a valuable complement to existing functional assays such as visual acuity, visual fields, and electroretinography. Whether employed in basic scientific research or clinical testing, the utility of ORG depends on its sensitivity to changes in the cone response. This sensitivity depends in part on the intrinsic variation of photoreceptor responses. In ORG studies using adaptive optics (AO), single cone responses are sometimes reported, but more often the responses of many cones are pooled in a defined field of view (FOV) to convey an average cone response with improved signal-to-noise ratio (SNR). In this study, we quantify repeatability of cellular-resolution ORG measurements made with adaptive optics (AO) optical coherence tomography (OCT). First, we describe a model-fitting method for parameterizing and quantifying the ORG responses. Next, using model-derived parameters, we investigate two kinds of repeatability: among repeated measurements of individual cones and among repeated measurements of the pooled responses of cones in a 1° field of view. Repeated measurements of individual cones exhibited good consistency in the ORG amplitude. Although responses among neighboring cones can differ greatly, pooled responses of cones from the same field of view were highly repeatable for maximum outer segment elongation and the elongation rate. Both kinds of repeatability were assessed using the same data sets; test-retest pairs were acquired within 30-minute windows in an effort to isolate measurement noise from physiological changes that may be more appropriately considered signal. These findings demonstrate AO-OCT-ORG’s potential value in detecting changes in cone response due to experimental or therapeutic interventions, and its value in measuring longitudinal disease-related changes in response.

Authors

Institutions

Publication Details

Journal
Biomedical Optics Express
Published
2026-04-14
DOI
https://doi.org/10.1364/boe.591181
Citations
1
Primary Topic
Optical Coherence Tomography Applications
Type
article
Field-Weighted Citation Impact
10.56
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Phase-based optoretinographic measurements of cones with a raster-scanning adaptive optics OCT are highly repeatable

Yao Cai, Robert Zawadzki, Maciej Bartuzel, Ravi Jonnal et al.
1 citations
Biomedical Optics Express
Optical Coherence Tomography Applications
10.56
article

Phase-based optoretinographic measurements of cones with a raster-scanning adaptive optics OCT are highly repeatable

Yao Cai, Robert Zawadzki, Maciej Bartuzel, Ravi Jonnal, Reddikumar Maddipatla
article en
1 citations

Abstract

Optoretinography (ORG) is a class of methods that use noninvasive, all-optical techniques to measure stimulus-evoked responses in the retina. By conveying functional and structural information at once, it offers a valuable complement to existing functional assays such as visual acuity, visual fields, and electroretinography. Whether employed in basic scientific research or clinical testing, the utility of ORG depends on its sensitivity to changes in the cone response. This sensitivity depends in part on the intrinsic variation of photoreceptor responses. In ORG studies using adaptive optics (AO), single cone responses are sometimes reported, but more often the responses of many cones are pooled in a defined field of view (FOV) to convey an average cone response with improved signal-to-noise ratio (SNR). In this study, we quantify repeatability of cellular-resolution ORG measurements made with adaptive optics (AO) optical coherence tomography (OCT). First, we describe a model-fitting method for parameterizing and quantifying the ORG responses. Next, using model-derived parameters, we investigate two kinds of repeatability: among repeated measurements of individual cones and among repeated measurements of the pooled responses of cones in a 1° field of view. Repeated measurements of individual cones exhibited good consistency in the ORG amplitude. Although responses among neighboring cones can differ greatly, pooled responses of cones from the same field of view were highly repeatable for maximum outer segment elongation and the elongation rate. Both kinds of repeatability were assessed using the same data sets; test-retest pairs were acquired within 30-minute windows in an effort to isolate measurement noise from physiological changes that may be more appropriately considered signal. These findings demonstrate AO-OCT-ORG’s potential value in detecting changes in cone response due to experimental or therapeutic interventions, and its value in measuring longitudinal disease-related changes in response.

Biomedical Optics ExpressVol. 17(5)
Wrocław University of Science and Technology (PL), University of California System (US), Nicolaus Copernicus University (PL)
Affordable and clean energy
Openalex Percentile: Top 2%
Optical Coherence Tomography Applications
10.56
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.