Reliability of fast T1 VIBE Dixon MRI for femoral version measurement in FAI patients: A comparative study with CT

Purpose: Patients with femoroacetabular impingement (FAI) can present with abnormal femoral version(FV). Discrepancies were reported for FV Measurement comparing MRI and CT. We assessed difference of FV measurement on MRI and on matched CT. Methods: A retrospective IRB-approved comparative study involving 100 hips of symptomatic FAI patients was performed. All patients(100 hips) had hip pain(mean age 28 ± 10 years) and underwent pelvic CT scan and MRI of the same hip. Routine unilateral, multiplanar MRI of the hip was acquired for chondrolabral lesions. Of them, 52 hips(46 patients) underwent hip MRI with standard T1 images, while 48 hips underwent hip MRI with an additional fast MRI with Dixon based images(bilateral T1 Vibe Dixon based images of pelvis and knee) to measure FV. Two readers independently measured FV(Murphy method) on CT and MRI. Results: Difference of FV decreased significantly(p < 0.001) between CT and MRI with standard images from 4.9 ± 4.5° for Reader 1(7.3 ± 6.7° for Reader 2) to -0.05 ± 1.5°(r = 0.993, p < 0.001)for Reader 1 (0.73 ± 2.95°, r = 0.975, p < 0.001, for Reader 2) with fast Dixon based images.Difference of FV of CT between two readers was 1.9 ± 3.2°(r = 0.969, p < 0.001) and was not significantly different compared to fast MRI with Dixon based images (1.1 ± 4.4°,r = 0.943, p < 0.001).Number of hips with Difference of FV> 5° between CT and MRI were significantly(p < 0.001) reduced from 35 hips (67%,with standard images) to 2 hips (4%, Dixon based images) for reader 1. Conclusion: We changed our clinical practice and use fast MRI with T1 Dixon-based images for FV measurement. This decreased measurement errors in FV and misdiagnosis of FV and could potentially reduce CT scans.

Authors

Institutions

Publication Details

Journal
European Journal of Radiology Open
Published
2026-04-14
DOI
https://doi.org/10.1016/j.ejro.2026.100745
Primary Topic
Hip disorders and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reliability of fast T1 VIBE Dixon MRI for femoral version measurement in FAI patients: A comparative study with CT

Tilman Kaim, Simon D. Steppacher, Malin K. Meier, Adam Boschung et al.
European Journal of Radiology Open
Hip disorders and treatments
article

Reliability of fast T1 VIBE Dixon MRI for femoral version measurement in FAI patients: A comparative study with CT

Tilman Kaim, Simon D. Steppacher, Malin K. Meier, Adam Boschung, Florian Schmaranzer, Till D. Lerch, Moritz Tannast
article en

Abstract

Purpose: Patients with femoroacetabular impingement (FAI) can present with abnormal femoral version(FV). Discrepancies were reported for FV Measurement comparing MRI and CT. We assessed difference of FV measurement on MRI and on matched CT. Methods: A retrospective IRB-approved comparative study involving 100 hips of symptomatic FAI patients was performed. All patients(100 hips) had hip pain(mean age 28 ± 10 years) and underwent pelvic CT scan and MRI of the same hip. Routine unilateral, multiplanar MRI of the hip was acquired for chondrolabral lesions. Of them, 52 hips(46 patients) underwent hip MRI with standard T1 images, while 48 hips underwent hip MRI with an additional fast MRI with Dixon based images(bilateral T1 Vibe Dixon based images of pelvis and knee) to measure FV. Two readers independently measured FV(Murphy method) on CT and MRI. Results: Difference of FV decreased significantly(p < 0.001) between CT and MRI with standard images from 4.9 ± 4.5° for Reader 1(7.3 ± 6.7° for Reader 2) to -0.05 ± 1.5°(r = 0.993, p < 0.001)for Reader 1 (0.73 ± 2.95°, r = 0.975, p < 0.001, for Reader 2) with fast Dixon based images.Difference of FV of CT between two readers was 1.9 ± 3.2°(r = 0.969, p < 0.001) and was not significantly different compared to fast MRI with Dixon based images (1.1 ± 4.4°,r = 0.943, p < 0.001).Number of hips with Difference of FV> 5° between CT and MRI were significantly(p < 0.001) reduced from 35 hips (67%,with standard images) to 2 hips (4%, Dixon based images) for reader 1. Conclusion: We changed our clinical practice and use fast MRI with T1 Dixon-based images for FV measurement. This decreased measurement errors in FV and misdiagnosis of FV and could potentially reduce CT scans.

European Journal of Radiology OpenVol. 16
University of Bern (CH), University Hospital of Bern (CH), Universitätsklinik Balgrist (CH)
Gender equality
Openalex Percentile: Top 26%
Hip disorders and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.