Comparative evaluation of collodion bag and HistoGel cell block techniques in effusion cytology: a prospective study of 117 specimens

INTRODUCTION: Cell block (CB) preparation enhances morphological evaluation and enables ancillary testing in effusion cytology. Although HistoGel is widely used, the collodion bag method has been historically recognized for improved cellular recovery but remains underutilized. This study aimed to compare the diagnostic performance, technical quality, reproducibility, and downstream utility of the collodion bag and HistoGel CB methods. MATERIALS AND METHODS: A prospective cross-sectional study was conducted on 117 effusion specimens. Samples were processed in parallel using collodion bag and HistoGel methods. Slides were independently scored by 3 pathologists using a five-parameter system. Paired comparisons were performed using the Wilcoxon signed-rank test. Interobserver agreement was assessed using intraclass correlation coefficients (ICCs). DNA yield was analyzed in 25 paired cases. RESULTS: The collodion bag method yielded significantly higher scores for artifact reduction (P= 0.0058), tissue contamination (P= 0.0280), cell distribution (P< 0.0001), and tumor burden (P< 0.0001). No significant difference was observed in cell preservation. Interobserver agreement was good for tumor burden (ICC = 0.789) and moderate for total score (ICC = 0.587). DNA concentration was higher in the collodion bag method compared with HistoGel (31.5 versus 28.3 ng/μL, P= 0.048), with a median paired difference of 7.1 ng/μL. The collodion bag method required longer preparation time but only slightly higher material cost. CONCLUSIONS: The collodion bag method provides improved morphologic quality and higher DNA yield compared with the HistoGel method, supporting its utility in optimizing CB preparation, particularly for cases requiring ancillary and molecular testing.

Authors

Institutions

Publication Details

Journal
Journal of the American Society of Cytopathology
Published
2026-04-01
DOI
https://doi.org/10.1016/j.jasc.2026.04.004
Primary Topic
Cancer and biochemical research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative evaluation of collodion bag and HistoGel cell block techniques in effusion cytology: a prospective study of 117 specimens

Sasithorn Watcharadetwittaya, Waritta Kunprom, Nipon Chaisuriya, Thanayot Techawijittra et al.
Journal of the American Society of Cytopathology
Cancer and biochemical research
article

Comparative evaluation of collodion bag and HistoGel cell block techniques in effusion cytology: a prospective study of 117 specimens

Sasithorn Watcharadetwittaya, Waritta Kunprom, Nipon Chaisuriya, Thanayot Techawijittra, Peeraya Trakulkajornsak
article en

Abstract

INTRODUCTION: Cell block (CB) preparation enhances morphological evaluation and enables ancillary testing in effusion cytology. Although HistoGel is widely used, the collodion bag method has been historically recognized for improved cellular recovery but remains underutilized. This study aimed to compare the diagnostic performance, technical quality, reproducibility, and downstream utility of the collodion bag and HistoGel CB methods. MATERIALS AND METHODS: A prospective cross-sectional study was conducted on 117 effusion specimens. Samples were processed in parallel using collodion bag and HistoGel methods. Slides were independently scored by 3 pathologists using a five-parameter system. Paired comparisons were performed using the Wilcoxon signed-rank test. Interobserver agreement was assessed using intraclass correlation coefficients (ICCs). DNA yield was analyzed in 25 paired cases. RESULTS: The collodion bag method yielded significantly higher scores for artifact reduction (P= 0.0058), tissue contamination (P= 0.0280), cell distribution (P< 0.0001), and tumor burden (P< 0.0001). No significant difference was observed in cell preservation. Interobserver agreement was good for tumor burden (ICC = 0.789) and moderate for total score (ICC = 0.587). DNA concentration was higher in the collodion bag method compared with HistoGel (31.5 versus 28.3 ng/μL, P= 0.048), with a median paired difference of 7.1 ng/μL. The collodion bag method required longer preparation time but only slightly higher material cost. CONCLUSIONS: The collodion bag method provides improved morphologic quality and higher DNA yield compared with the HistoGel method, supporting its utility in optimizing CB preparation, particularly for cases requiring ancillary and molecular testing.

Journal of the American Society of Cytopathology
Khon Kaen University (TH)
Khon Kaen University
Zero hunger
Openalex Percentile: Top 28%
Cancer and biochemical research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.