Malposition of the Selective Antegrade Cerebral Perfusion Catheter Identified by Carotid Ultrasonography: A Case Report

ABSTRACT: Cerebral hypoperfusion can occur during aortic surgery. We present a case in which malposition of the selective antegrade cerebral perfusion (SACP) catheter was identified using carotid ultrasonography. A 66-year-old man underwent total arch replacement. SACP was initiated via the brachiocephalic artery following deep hypothermic circulatory arrest. However, right forehead regional oxygen saturation (rSO2) remained unchanged. Carotid ultrasonography revealed no blood flow in the right common carotid artery, suggesting catheter malposition into the right subclavian artery. After a slight catheter withdrawal, blood flow was restored, and rSO2 increased. Carotid ultrasonography, along with rSO2 monitoring, is recommended for evaluating cerebral perfusion during SACP.

Authors

Institutions

Publication Details

Journal
Annals of Cardiac Anaesthesia
Published
2026-04-01
DOI
https://doi.org/10.4103/aca.aca_51_25
Primary Topic
Aortic Disease and Treatment Approaches
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Malposition of the Selective Antegrade Cerebral Perfusion Catheter Identified by Carotid Ultrasonography: A Case Report

Yuji Kunitoku, Taisuke Kumamoto, Takahiro Fukuda
Annals of Cardiac Anaesthesia
Aortic Disease and Treatment Approaches
article

Malposition of the Selective Antegrade Cerebral Perfusion Catheter Identified by Carotid Ultrasonography: A Case Report

Yuji Kunitoku, Taisuke Kumamoto, Takahiro Fukuda
article en

Abstract

ABSTRACT: Cerebral hypoperfusion can occur during aortic surgery. We present a case in which malposition of the selective antegrade cerebral perfusion (SACP) catheter was identified using carotid ultrasonography. A 66-year-old man underwent total arch replacement. SACP was initiated via the brachiocephalic artery following deep hypothermic circulatory arrest. However, right forehead regional oxygen saturation (rSO2) remained unchanged. Carotid ultrasonography revealed no blood flow in the right common carotid artery, suggesting catheter malposition into the right subclavian artery. After a slight catheter withdrawal, blood flow was restored, and rSO2 increased. Carotid ultrasonography, along with rSO2 monitoring, is recommended for evaluating cerebral perfusion during SACP.

Annals of Cardiac AnaesthesiaVol. 29(2)
Saiseikai Kumamoto Hospital (JP)
Good health and well-being
Openalex Percentile: Top 17%
Aortic Disease and Treatment Approaches
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.