Uncertainty Pattern Recognition of Multi-Type Renewable Power Plants and the Coupling Mechanism with Multi-Level Voltage Sensitivity

With high penetrations of renewable power plants, increased output volatility and uncertainty exacerbate local voltage-stability risks. Targeting heterogeneous renewable facilities, this paper proposes an integrated analysis framework that couples deep feature disentanglement, joint forecasting, and multi-level voltage sensitivity. First, using event logs as the driver, we combine variational mode decomposition (VMD) with a residual convolutional autoencoder (Res-CAE) to extract multi-band disturbance modes from power time series. An adversarial mechanism is then employed to disentangle meteorological disturbances from device-driven behaviors, yielding canonical uncertainty labels dominated by high-/mid-frequency components. Next, a spatio-temporal attention–driven multi-task sequence model is designed to jointly forecast active/reactive power and nodal voltage, providing stable inputs for subsequent sensitivity assessment. Finally, dynamic voltage sensitivity is estimated via sliding-window regression, and the disturbance–response chain and its propagation scope are quantified across local, dynamic, and system-level tiers. Event-driven simulations on the SoCal 28-Bus benchmark indicate that, under high- and mid-frequency dominated scenarios, dynamic voltage sensitivity increases by approximately 58.3% relative to low-volatility regimes, revealing a nonlinear transition by which renewable uncertainty is amplified through multi-frequency modes toward critical nodes. The proposed paradigm offers a transferable pathway for modeling and predicting complex source–network coupling in renewable-dominated power systems and provides data support for proactive voltage-control strategy design.

Authors

Institutions

Publication Details

Journal
EAI Endorsed Transactions on Energy Web
Published
2026-04-14
DOI
https://doi.org/10.4108/ew.12177
Primary Topic
Power System Optimization and Stability
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Uncertainty Pattern Recognition of Multi-Type Renewable Power Plants and the Coupling Mechanism with Multi-Level Voltage Sensitivity

Zhi Zhang, Xiaoyu Luo, Yulong Li, Lili Lv et al.
EAI Endorsed Transactions on Energy Web
Power System Optimization and Stability
article

Uncertainty Pattern Recognition of Multi-Type Renewable Power Plants and the Coupling Mechanism with Multi-Level Voltage Sensitivity

Zhi Zhang, Xiaoyu Luo, Yulong Li, Lili Lv, Li Xiong, Xin Zhou, Lei Zhuo, Mingzhao Meng
article en

Abstract

With high penetrations of renewable power plants, increased output volatility and uncertainty exacerbate local voltage-stability risks. Targeting heterogeneous renewable facilities, this paper proposes an integrated analysis framework that couples deep feature disentanglement, joint forecasting, and multi-level voltage sensitivity. First, using event logs as the driver, we combine variational mode decomposition (VMD) with a residual convolutional autoencoder (Res-CAE) to extract multi-band disturbance modes from power time series. An adversarial mechanism is then employed to disentangle meteorological disturbances from device-driven behaviors, yielding canonical uncertainty labels dominated by high-/mid-frequency components. Next, a spatio-temporal attention–driven multi-task sequence model is designed to jointly forecast active/reactive power and nodal voltage, providing stable inputs for subsequent sensitivity assessment. Finally, dynamic voltage sensitivity is estimated via sliding-window regression, and the disturbance–response chain and its propagation scope are quantified across local, dynamic, and system-level tiers. Event-driven simulations on the SoCal 28-Bus benchmark indicate that, under high- and mid-frequency dominated scenarios, dynamic voltage sensitivity increases by approximately 58.3% relative to low-volatility regimes, revealing a nonlinear transition by which renewable uncertainty is amplified through multi-frequency modes toward critical nodes. The proposed paradigm offers a transferable pathway for modeling and predicting complex source–network coupling in renewable-dominated power systems and provides data support for proactive voltage-control strategy design.

EAI Endorsed Transactions on Energy WebVol. 12
Power Grid Corporation (India) (IN)
China Southern Power Grid
Affordable and clean energy
Openalex Percentile: Top 27%
Power System Optimization and Stability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.