<scp>ROLL</scp> Is Successful at Localising Axillary Lymph Nodes: A Single Tertiary Centre Experience

BACKGROUND: In breast malignancy, localisation of axillary nodes is crucial for guiding targeted axillary dissection (TAD), particularly following neoadjuvant chemotherapy (NACT). While many localisation techniques exist, many have limitations with flexibility in scheduling, patient discomfort or issues with implantables (e.g., radioactive seeds, radar reflectors or magnetic markers). Ultrasound-guided Radioguided Occult Lesion Localisation (ROLL) was originally used for non-palpable breast lesions and relatively new in localisation of axillary lymph nodes. The authors aim to share the experience of ROLL in this single tertiary centre. MATERIAL AND METHODS: From March 2020 to December 2024, 41 suspicious axillary nodes from 30 patients who underwent ultrasound guided ROLL were included in this study. RESULTS: The technical success rate was 95.1% (39/41 nodes) as confirmed by the appreciation of radioisotope in post-injection scintigraphy and subsequent intra-operative localisation. Among 21 patients (26 nodes) who underwent NACT, the mean size of lymph node pre- and post-NACT was 2.1 cm (1.0-4.3 cm) and 1.2 cm (0.7-3.2 cm), respectively. The distance from lymph node to skin was 1.5 cm (0.8-2.5 cm). The primary pathology was breast cancer in 26 patients (33 nodes). A tissue marker clip was inserted into 27 (65.9%) lymph nodes. Main technical challenges include small or deep lymph nodes and those that are either unclipped or marked with clips demonstrating limited sonographic visibility. CONCLUSION: Ultrasound-guided ROLL is an effective method for localising axillary lymph nodes, including small, deep or clipped/unclipped nodes that are challenging to identify. This technique offers improved patient comfort and logistical flexibility, and its high accuracy provides a strong argument for its role in TAD.

Authors

Institutions

Publication Details

Journal
Journal of Medical Imaging and Radiation Oncology
Published
2026-04-13
DOI
https://doi.org/10.1111/1754-9485.70102
Primary Topic
Lymphadenopathy Diagnosis and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ROLL Is Successful at Localising Axillary Lymph Nodes: A Single Tertiary Centre Experience

Qing Tan, Yien Sien Lee, Veronica Siton Alcantara, Hiok Yang Chan et al.
Journal of Medical Imaging and Radiation Oncology
Lymphadenopathy Diagnosis and Analysis
article

ROLL Is Successful at Localising Axillary Lymph Nodes: A Single Tertiary Centre Experience

Qing Tan, Yien Sien Lee, Veronica Siton Alcantara, Hiok Yang Chan, Amini Mursal
article en

Abstract

BACKGROUND: In breast malignancy, localisation of axillary nodes is crucial for guiding targeted axillary dissection (TAD), particularly following neoadjuvant chemotherapy (NACT). While many localisation techniques exist, many have limitations with flexibility in scheduling, patient discomfort or issues with implantables (e.g., radioactive seeds, radar reflectors or magnetic markers). Ultrasound-guided Radioguided Occult Lesion Localisation (ROLL) was originally used for non-palpable breast lesions and relatively new in localisation of axillary lymph nodes. The authors aim to share the experience of ROLL in this single tertiary centre. MATERIAL AND METHODS: From March 2020 to December 2024, 41 suspicious axillary nodes from 30 patients who underwent ultrasound guided ROLL were included in this study. RESULTS: The technical success rate was 95.1% (39/41 nodes) as confirmed by the appreciation of radioisotope in post-injection scintigraphy and subsequent intra-operative localisation. Among 21 patients (26 nodes) who underwent NACT, the mean size of lymph node pre- and post-NACT was 2.1 cm (1.0-4.3 cm) and 1.2 cm (0.7-3.2 cm), respectively. The distance from lymph node to skin was 1.5 cm (0.8-2.5 cm). The primary pathology was breast cancer in 26 patients (33 nodes). A tissue marker clip was inserted into 27 (65.9%) lymph nodes. Main technical challenges include small or deep lymph nodes and those that are either unclipped or marked with clips demonstrating limited sonographic visibility. CONCLUSION: Ultrasound-guided ROLL is an effective method for localising axillary lymph nodes, including small, deep or clipped/unclipped nodes that are challenging to identify. This technique offers improved patient comfort and logistical flexibility, and its high accuracy provides a strong argument for its role in TAD.

Journal of Medical Imaging and Radiation Oncology
KK Women's and Children's Hospital (SG)
Openalex Percentile: Top 18%
Lymphadenopathy Diagnosis and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.