Airway and Ventilation Rescue During Tracheal Resection: A Case Report of Intraoperative Troubleshooting

Tracheal resection requires shared airway management when conventional ventilation fails. The present paper describes a 73-year-old man with chronic obstructive pulmonary disease (COPD), hypertension, and prior neck radiotherapy who underwent tracheal resection with primary anastomosis for chondrosarcoma. Initial intubation with a single-lumen endobronchial tube produced a major leak, requiring exchange to an endotracheal tube. Lung isolation with an EZ blocker® (Teleflex Life Sciences Ltd., Athlone, Ireland) was achieved but lost during thoracotomy in the lateral decubitus position with a chin stitch; an Arndt blocker also failed. Ventilation transitioned to high-frequency jet ventilation with intermittent apnea, cross-field ventilation, and intermittent endotracheal tube ventilation. A cuff rupture causing a leak was managed with cuff inflation, allowing successful extubation. The patient remained hemodynamically stable without complications and was discharged one week postoperatively at his functional baseline, with adequate oxygenation, good pain control, and full independence.

Authors

Publication Details

Journal
Cureus
Published
2026-04-14
DOI
https://doi.org/10.7759/cureus.107007
Primary Topic
Tracheal and airway disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Airway and Ventilation Rescue During Tracheal Resection: A Case Report of Intraoperative Troubleshooting

Taha B. Aljishi, Sylvain Gagné, Calvin Thompson, Donna Maziak et al.
Cureus
Tracheal and airway disorders
article

Airway and Ventilation Rescue During Tracheal Resection: A Case Report of Intraoperative Troubleshooting

Taha B. Aljishi, Sylvain Gagné, Calvin Thompson, Donna Maziak, Ryan McGinn
article en

Abstract

Tracheal resection requires shared airway management when conventional ventilation fails. The present paper describes a 73-year-old man with chronic obstructive pulmonary disease (COPD), hypertension, and prior neck radiotherapy who underwent tracheal resection with primary anastomosis for chondrosarcoma. Initial intubation with a single-lumen endobronchial tube produced a major leak, requiring exchange to an endotracheal tube. Lung isolation with an EZ blocker® (Teleflex Life Sciences Ltd., Athlone, Ireland) was achieved but lost during thoracotomy in the lateral decubitus position with a chin stitch; an Arndt blocker also failed. Ventilation transitioned to high-frequency jet ventilation with intermittent apnea, cross-field ventilation, and intermittent endotracheal tube ventilation. A cuff rupture causing a leak was managed with cuff inflation, allowing successful extubation. The patient remained hemodynamically stable without complications and was discharged one week postoperatively at his functional baseline, with adequate oxygenation, good pain control, and full independence.

Cureus
Responsible consumption and production
Openalex Percentile: Top 8%
Tracheal and airway disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.