Climate-Dependent Performance of Natural Ventilation Under Continuous 24-h Mechanical Ventilation in Residential Buildings

Natural ventilation is widely regarded as an energy-saving strategy in buildings; however, under continuous mechanical ventilation in Japanese residential buildings, its performance remains insufficiently understood. This study evaluates the performance of different natural ventilation strategies for a typical two-story detached house across eight climate zones in Japan using dynamic building energy simulation. Four ventilation strategies are examined, including baseline mechanical ventilation (S0), shoulder-season natural ventilation (S1), summer night ventilation (S2), and an adaptive natural ventilation strategy with humidity constraints (S3). Annual HVAC loads, monthly variations, and the structure of cooling loads are analyzed. Results show that shoulder-season natural ventilation (S1) does not lead to energy savings and may result in a slight increase in annual HVAC loads in most climate zones. In contrast, summer night ventilation (S2) reduces annual HVAC loads by approximately 8–10% in transitional climates (CZ3–CZ5), while its effect is weaker in hot and humid regions. The adaptive strategy (S3) achieves moderate reductions of up to about 2–3% and significantly decreases the proportion of latent cooling loads. Overall, the effectiveness of natural ventilation is governed by the trade-off between sensible load reduction and latent load increase and is strongly climate-dependent. These findings provide a basis for optimizing hybrid ventilation strategies under continuous mechanical ventilation conditions.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2026-04-14
DOI
https://doi.org/10.3390/buildings16081545
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Climate-Dependent Performance of Natural Ventilation Under Continuous 24-h Mechanical Ventilation in Residential Buildings

Xiangru Kong, Weijun Gao, Yufan Ren
Buildings
Building Energy and Comfort Optimization
article

Climate-Dependent Performance of Natural Ventilation Under Continuous 24-h Mechanical Ventilation in Residential Buildings

Xiangru Kong, Weijun Gao, Yufan Ren
article en

Abstract

Natural ventilation is widely regarded as an energy-saving strategy in buildings; however, under continuous mechanical ventilation in Japanese residential buildings, its performance remains insufficiently understood. This study evaluates the performance of different natural ventilation strategies for a typical two-story detached house across eight climate zones in Japan using dynamic building energy simulation. Four ventilation strategies are examined, including baseline mechanical ventilation (S0), shoulder-season natural ventilation (S1), summer night ventilation (S2), and an adaptive natural ventilation strategy with humidity constraints (S3). Annual HVAC loads, monthly variations, and the structure of cooling loads are analyzed. Results show that shoulder-season natural ventilation (S1) does not lead to energy savings and may result in a slight increase in annual HVAC loads in most climate zones. In contrast, summer night ventilation (S2) reduces annual HVAC loads by approximately 8–10% in transitional climates (CZ3–CZ5), while its effect is weaker in hot and humid regions. The adaptive strategy (S3) achieves moderate reductions of up to about 2–3% and significantly decreases the proportion of latent cooling loads. Overall, the effectiveness of natural ventilation is governed by the trade-off between sensible load reduction and latent load increase and is strongly climate-dependent. These findings provide a basis for optimizing hybrid ventilation strategies under continuous mechanical ventilation conditions.

BuildingsVol. 16(8)
Sepuluh Nopember Institute of Technology (ID), The University of Kitakyushu (JP), Zhejiang Province Institute of Architectural Design and Research (CN), Qingdao University of Technology (CN), Zhejiang University (CN)
Climate action
Openalex Percentile: Top 25%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Climate-Dependent Performance of Natural Ventilation Under Continuous 24-h Mechanical Ventilation in Residential Buildings — Xiangru Kong, Weijun Gao, et al. · Buildings (2026) | TGRS Research Map | TGRS