Theoretical modelling and optimization design of PMUT arrays for enhanced acoustic performance

Theoretical models are essential for performance analysis and structure optimization design of large-scale piezoelectric micromachined ultrasonic transducers (PMUT) arrays. However, current models have rarely incorporated the inter-element crosstalk and oversimplified the electro-mechanical-acoustic coupling, leading serious discrepancies with experimental results and limiting the array optimization design and performance improvement. To address this, a novel electro-mechanical-acoustic coupling model and a spatial acoustic field modeling approach are proposed for PMUT arrays, incorporating distributed deformation functions of individual element and mutual acoustic impedance to analyse key performance metrics such as transmission power, frequency response, focal length, and beamwidth. Its accuracy is validated through finite element simulations, demonstrating small deviations of less than 3%. Parametric studies reveal that increasing the filling ratio from 20% to 60% improves transmission power and bandwidth but significantly increases crosstalk, reducing focusing efficiency. Enlarging the array size results in proportional increases in acoustic output power and focal pressure, while simultaneously reducing beamwidth, thereby improving directivity. As for array arrangements, circular array achieves higher focal pressure than square array, albeit with shorter focal lengths. Annular array, with its distinct mainlobe and ring-shaped sidelobes, demonstrates superior focal pressure at longer distances, ideal for extended-range applications. The theoretical models are further validated by experimental results from fabricated square, hexagonal, circular, and annular PMUT arrays. This study proposes an accurate theoretical model for PMUT arrays, enabling accurate and reliable prediction of key acoustic performance metrics in large-scale arrays, and facilitating the array structure optimization design and performance enhancement of PMUT.

Authors

Institutions

Publication Details

Journal
Microsystems & Nanoengineering
Published
2026-04-14
DOI
https://doi.org/10.1038/s41378-026-01159-7
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Theoretical modelling and optimization design of PMUT arrays for enhanced acoustic performance

L F Fan, Ran Dong, Zilong Zhao, Kui Zhang et al.
Microsystems & Nanoengineering
Ultrasound Imaging and Elastography
article

Theoretical modelling and optimization design of PMUT arrays for enhanced acoustic performance

L F Fan, Ran Dong, Zilong Zhao, Kui Zhang, Dejiang Lu, Z K Li, Hongqiang Tan, Jiawei Yuan, Zimeng Zhang, Yihe Zhao, Xiaozhang Wang, Min Li, Shaohui Qin
article en

Abstract

Theoretical models are essential for performance analysis and structure optimization design of large-scale piezoelectric micromachined ultrasonic transducers (PMUT) arrays. However, current models have rarely incorporated the inter-element crosstalk and oversimplified the electro-mechanical-acoustic coupling, leading serious discrepancies with experimental results and limiting the array optimization design and performance improvement. To address this, a novel electro-mechanical-acoustic coupling model and a spatial acoustic field modeling approach are proposed for PMUT arrays, incorporating distributed deformation functions of individual element and mutual acoustic impedance to analyse key performance metrics such as transmission power, frequency response, focal length, and beamwidth. Its accuracy is validated through finite element simulations, demonstrating small deviations of less than 3%. Parametric studies reveal that increasing the filling ratio from 20% to 60% improves transmission power and bandwidth but significantly increases crosstalk, reducing focusing efficiency. Enlarging the array size results in proportional increases in acoustic output power and focal pressure, while simultaneously reducing beamwidth, thereby improving directivity. As for array arrangements, circular array achieves higher focal pressure than square array, albeit with shorter focal lengths. Annular array, with its distinct mainlobe and ring-shaped sidelobes, demonstrates superior focal pressure at longer distances, ideal for extended-range applications. The theoretical models are further validated by experimental results from fabricated square, hexagonal, circular, and annular PMUT arrays. This study proposes an accurate theoretical model for PMUT arrays, enabling accurate and reliable prediction of key acoustic performance metrics in large-scale arrays, and facilitating the array structure optimization design and performance enhancement of PMUT.

Microsystems & NanoengineeringVol. 12(1)
Capital Medical University (CN), Yantai University (CN), Beijing Anzhen Hospital (CN), First Affiliated Hospital of Xi'an Jiaotong University (CN), Xi'an Jiaotong University (CN)
National Natural Science Foundation of China, National Key Research and Development Program of China
Affordable and clean energy
Openalex Percentile: Top 21%
Ultrasound Imaging and Elastography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.