Automated montaging and contrast stretching of adaptive optics ophthalmoscope images

We present an automated montaging method for distortion-corrected single- and multi-channel adaptive optics ophthalmoscope images. The approach employs a zero-mean normalized weighted cross-correlation (ZNWCC) that enables assigning real-valued pixel weights to account for irregular image boundaries, spatially varying signal-to-noise ratio, and motion of retinal features. An initial sub-pixel pairwise registration using translation, rotation, and, if needed, scaling is refined with a global registration quality metric derived from peak ZNWCC values. The images are montaged through weighted averaging and contrast stretching that equalize mean image brightness and contrast in overlapping regions, compensating for differences in overall illumination, detector offset, and detector gain. A final montage is created by combining the transformed images calculated through a single interpolation to mitigate loss of resolution, and with an optional polynomial field-flattening step to increase contrast throughout the montage. The method is demonstrated on AO retinal image sets from human and mouse eyes.

Authors

Publication Details

Journal
Biomedical Optics Express
Published
2026-04-14
DOI
https://doi.org/10.1364/boe.591748
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automated montaging and contrast stretching of adaptive optics ophthalmoscope images

Karteek Kunala, Alfredo Dubra, Gastón Ayubi
Biomedical Optics Express
Ophthalmology and Visual Impairment Studies
article

Automated montaging and contrast stretching of adaptive optics ophthalmoscope images

Karteek Kunala, Alfredo Dubra, Gastón Ayubi
article en

Abstract

We present an automated montaging method for distortion-corrected single- and multi-channel adaptive optics ophthalmoscope images. The approach employs a zero-mean normalized weighted cross-correlation (ZNWCC) that enables assigning real-valued pixel weights to account for irregular image boundaries, spatially varying signal-to-noise ratio, and motion of retinal features. An initial sub-pixel pairwise registration using translation, rotation, and, if needed, scaling is refined with a global registration quality metric derived from peak ZNWCC values. The images are montaged through weighted averaging and contrast stretching that equalize mean image brightness and contrast in overlapping regions, compensating for differences in overall illumination, detector offset, and detector gain. A final montage is created by combining the transformed images calculated through a single interpolation to mitigate loss of resolution, and with an optional polynomial field-flattening step to increase contrast throughout the montage. The method is demonstrated on AO retinal image sets from human and mouse eyes.

Biomedical Optics ExpressVol. 17(5)
Advanced Research Projects Agency for Health
Openalex Percentile: Top 14%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.