Development of a cooling capacity correlation for aluminum tube evaporator to enhance refrigerator efficiency using R600a refrigerant

Abstract This paper focuses on the cooling capacity analysis of aluminium tube evaporator for cooling compartments in domestic refrigerator. The study adapted a framework combining analytical and experimental analyses to investigate the influence of evaporator tube length on the cooling capacity of the freezer and refrigerator. Convective heat transfer co-efficient based on two-phase flow was calculated under four different correlations considering a domestic refrigerator of 246 L volume using R600a refrigerant. Cooling capacity was calculated based on the product of cooling capacity factor and cubic root of volume signifying the heat loss. The cooling capacity factor provides a concrete understanding of the variation in evaporator tube length as a function of different parameters such as thermal conductivity, thickness, temperature etc. An optimized evaporator tube length was considered for the freezer and refrigerator of 246 L domestic refrigerator bestowing uniform cooling capacity factor for four different correlations albeit convective heat transfer coefficient (HTC) varied significantly. To validate the optimized evaporator tube lengths, cooling capacity was examined through pull-down tests for two different commercially available samples of varying volumes and tube lengths for the freezer and refrigerator, as well as the optimized sample with the largest volume. A comparison of the cooling capacity of the two samples and the optimized sample showed that the optimized sample exhibited a higher cooling capacity and achieved temperature convergence earlier. Furthermore, the energy analysis conducted on all samples revealed that optimized sample attained the highest energy efficiency ratio (EER) and least Energy Efficiency Index (EEI).

Authors

Institutions

Publication Details

Journal
International Journal of Air-Conditioning and Refrigeration
Published
2026-04-14
DOI
https://doi.org/10.1007/s44189-026-00104-7
Primary Topic
Heat Transfer and Boiling Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a cooling capacity correlation for aluminum tube evaporator to enhance refrigerator efficiency using R600a refrigerant

Md. Moeenul Haque, Mohammad Tauhiduzzaman, Asm Toufiq Imam, Satwat Ahmed
International Journal of Air-Conditioning and Refrigeration
Heat Transfer and Boiling Studies
article

Development of a cooling capacity correlation for aluminum tube evaporator to enhance refrigerator efficiency using R600a refrigerant

Md. Moeenul Haque, Mohammad Tauhiduzzaman, Asm Toufiq Imam, Satwat Ahmed
article en

Abstract

Abstract This paper focuses on the cooling capacity analysis of aluminium tube evaporator for cooling compartments in domestic refrigerator. The study adapted a framework combining analytical and experimental analyses to investigate the influence of evaporator tube length on the cooling capacity of the freezer and refrigerator. Convective heat transfer co-efficient based on two-phase flow was calculated under four different correlations considering a domestic refrigerator of 246 L volume using R600a refrigerant. Cooling capacity was calculated based on the product of cooling capacity factor and cubic root of volume signifying the heat loss. The cooling capacity factor provides a concrete understanding of the variation in evaporator tube length as a function of different parameters such as thermal conductivity, thickness, temperature etc. An optimized evaporator tube length was considered for the freezer and refrigerator of 246 L domestic refrigerator bestowing uniform cooling capacity factor for four different correlations albeit convective heat transfer coefficient (HTC) varied significantly. To validate the optimized evaporator tube lengths, cooling capacity was examined through pull-down tests for two different commercially available samples of varying volumes and tube lengths for the freezer and refrigerator, as well as the optimized sample with the largest volume. A comparison of the cooling capacity of the two samples and the optimized sample showed that the optimized sample exhibited a higher cooling capacity and achieved temperature convergence earlier. Furthermore, the energy analysis conducted on all samples revealed that optimized sample attained the highest energy efficiency ratio (EER) and least Energy Efficiency Index (EEI).

International Journal of Air-Conditioning and RefrigerationVol. 34(1)
American International University-Bangladesh (BD), Khulna University of Engineering and Technology (BD), Bangladesh University of Engineering and Technology (BD), De Montfort University (GB)
Affordable and clean energy
Openalex Percentile: Top 26%
Heat Transfer and Boiling Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.