Case study: Impact of flame straightening on performances of preset beam ends in a steel corridor

Abstract Flame straightening corrects deviations in steel structures but induces residual stresses and microstructural alterations, potentially affecting safety. This study evaluates its impact on preset beam ends for a steel corridor connection. Deviations resulted from differential building settlement and thermal torsional deformation. A cyclic vein heating process (up to 800 °C) was simulated on a Q355B steel beam end using Abaqus coupled temperature–displacement analysis to generate the residual stress field, which was then used as an initial condition in mechanical analysis. The bearing capacity, energy dissipation under cyclic loading, and fatigue life under wind loads were compared before and after straightening. Results indicate that flame straightening has negligible effects on ultimate bearing capacity and displacement ability. It may slightly enhance energy dissipation at small displacements due to earlier localized yielding. Importantly, while fatigue life remains adequate for designed wind loads, it degrades significantly under high‐stress fatigue conditions. Thus, flame straightening is a viable correction method under moderate service loads but is not recommended for members experiencing high‐stress dynamic or fatigue loading.

Authors

Institutions

Publication Details

Journal
Steel Construction
Published
2026-04-14
DOI
https://doi.org/10.1002/stco.70025
Primary Topic
Fire effects on concrete materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Case study: Impact of flame straightening on performances of preset beam ends in a steel corridor

Chun-ming Wei, 李升才, He Zhang, Fanyu Wu et al.
Steel Construction
Fire effects on concrete materials
article

Case study: Impact of flame straightening on performances of preset beam ends in a steel corridor

Chun-ming Wei, 李升才, He Zhang, Fanyu Wu, Kun Wang, Zhi‐jun Jiang
article en

Abstract

Abstract Flame straightening corrects deviations in steel structures but induces residual stresses and microstructural alterations, potentially affecting safety. This study evaluates its impact on preset beam ends for a steel corridor connection. Deviations resulted from differential building settlement and thermal torsional deformation. A cyclic vein heating process (up to 800 °C) was simulated on a Q355B steel beam end using Abaqus coupled temperature–displacement analysis to generate the residual stress field, which was then used as an initial condition in mechanical analysis. The bearing capacity, energy dissipation under cyclic loading, and fatigue life under wind loads were compared before and after straightening. Results indicate that flame straightening has negligible effects on ultimate bearing capacity and displacement ability. It may slightly enhance energy dissipation at small displacements due to earlier localized yielding. Importantly, while fatigue life remains adequate for designed wind loads, it degrades significantly under high‐stress fatigue conditions. Thus, flame straightening is a viable correction method under moderate service loads but is not recommended for members experiencing high‐stress dynamic or fatigue loading.

Steel Construction
China Huadian Corporation (China) (CN), Yangzhou University (CN)
Openalex Percentile: Top 15%
Fire effects on concrete materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.