Comparative 1-year outcomes of pentaspline versus circular array pulsed field ablation for pulmonary vein isolation with adjunctive atrial lines

BACKGROUND: Pulsed field ablation (PFA) has emerged as an effective and safe single-shot technology for pulmonary vein isolation (PVI) in atrial fibrillation (AF). However, comparative long-term outcome data between different PFA catheter designs, particularly for additional atrial ablation beyond PVI, remain scarce. OBJECTIVE: This study aimed to compare 1-year clinical outcomes and procedural performance of pentaspline versus circular PFA catheters for PVI with additional left atrial roof line ablation (LARA). METHODS: ). The primary end point was freedom from atrial arrhythmia after a 3-month blanking period. RESULTS: A total of 200 patients were included (65% male, 44% persistent AF, median age 66 [interquartile range {IQR} 59-74] years), with 100 patients per group and no baseline differences. LARA was performed in 30% (30/100) of pentaspline and 32% (32/100) of circular PFA procedures, respectively. Acute PVI and bidirectional block of all additional lines were achieved in 100% of cases. Median procedure time (63 [IQR 54-77] vs 67 [IQR 59-80] min; P = .06) and fluoroscopy time (11.9 [9.8-15.2] vs 13.2 [10.2-15.9] min; P = .203) were comparable. Overall complication rates were low and similar (5% vs 3%). During a median follow-up of 386 (IQR 349-486) days, 1-year arrhythmia-free survival was similar between pentaspline and circular PFA catheters (81.7% vs 81.8%; log-rank P = .90), with comparable outcomes in paroxysmal and persistent AF. CONCLUSION: Pentaspline and circular PFA catheters demonstrate comparable safety, procedural performance, and 1-year clinical efficacy for PVI and LARA. These findings support the feasibility of comprehensive PFA-based atrial ablation strategies in patients with persistent atrial fibrillation and enlarged left atria.

Authors

Institutions

Publication Details

Journal
Heart Rhythm
Published
2026-04-01
DOI
https://doi.org/10.1016/j.hrthm.2026.03.1914
Primary Topic
Cardiac Arrhythmias and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative 1-year outcomes of pentaspline versus circular array pulsed field ablation for pulmonary vein isolation with adjunctive atrial lines

Andreas Hain, Joerg Yogarajah, Malte Kuniss, Julie Hutter et al.
Heart Rhythm
Cardiac Arrhythmias and Treatments
article

Comparative 1-year outcomes of pentaspline versus circular array pulsed field ablation for pulmonary vein isolation with adjunctive atrial lines

Andreas Hain, Joerg Yogarajah, Malte Kuniss, Julie Hutter, Philipp Beaujean, Mirlinda Lüsebrink, Marko Tomic, T Neumann, S T Sossalla, Patrick Kahle
article en

Abstract

BACKGROUND: Pulsed field ablation (PFA) has emerged as an effective and safe single-shot technology for pulmonary vein isolation (PVI) in atrial fibrillation (AF). However, comparative long-term outcome data between different PFA catheter designs, particularly for additional atrial ablation beyond PVI, remain scarce. OBJECTIVE: This study aimed to compare 1-year clinical outcomes and procedural performance of pentaspline versus circular PFA catheters for PVI with additional left atrial roof line ablation (LARA). METHODS: ). The primary end point was freedom from atrial arrhythmia after a 3-month blanking period. RESULTS: A total of 200 patients were included (65% male, 44% persistent AF, median age 66 [interquartile range {IQR} 59-74] years), with 100 patients per group and no baseline differences. LARA was performed in 30% (30/100) of pentaspline and 32% (32/100) of circular PFA procedures, respectively. Acute PVI and bidirectional block of all additional lines were achieved in 100% of cases. Median procedure time (63 [IQR 54-77] vs 67 [IQR 59-80] min; P = .06) and fluoroscopy time (11.9 [9.8-15.2] vs 13.2 [10.2-15.9] min; P = .203) were comparable. Overall complication rates were low and similar (5% vs 3%). During a median follow-up of 386 (IQR 349-486) days, 1-year arrhythmia-free survival was similar between pentaspline and circular PFA catheters (81.7% vs 81.8%; log-rank P = .90), with comparable outcomes in paroxysmal and persistent AF. CONCLUSION: Pentaspline and circular PFA catheters demonstrate comparable safety, procedural performance, and 1-year clinical efficacy for PVI and LARA. These findings support the feasibility of comprehensive PFA-based atrial ablation strategies in patients with persistent atrial fibrillation and enlarged left atria.

Heart Rhythm
Justus-Liebig-Universität Gießen (DE), Kerckhoff Klinik (DE)
Zero hunger
Openalex Percentile: Top 25%
Cardiac Arrhythmias and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.