A Modeling and Calculation Method for Faults in the Distribution Network Connected to VSG-Type DGs

Conventional fault analysis and calculation methods developed for synchronous-generator-dominated power systems exhibit limited applicability to distribution networks with high penetration of distributed generation (DG). These methods cannot provide a reliable theoretical basis for fault characteristic analysis or protection coordination. Existing studies on this scenario have primarily focused on the integration of grid-following (GFL) inverter-based resources (IBRs). By contrast, research on the integration of grid-forming (GFM) IBRs—particularly the virtual synchronous generator (VSG), which enables stable and sustainable utilization of renewable energy resources as synchronous generators—remains significantly inadequate. Therefore, this paper introduces a concise fault analysis and calculation method tailored to distribution networks with VSG-type DGs. First, the control strategy of the VSG-type DGs is examined, and the active-power response characteristics of VSG-type DGs are analyzed for faults in distribution networks. Equivalent models of a typical distribution network with VSG-type DGs are then established for symmetrical and asymmetrical faults. Subsequently, leveraging the active power–frequency and reactive power–voltage dependencies, a fault calculation method for distribution networks is proposed and its generality is examined. The method is convenient to implement and computationally efficient. It requires no detailed information on internal PI controller parameters or time constants of the control loops. PSCAD/EMTDC simulations are performed to verify the high accuracy and suitability of the proposed method for multi-DG scenarios, which facilitates the integration of VSG-type DGs in distribution networks.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2026-04-11
DOI
https://doi.org/10.3390/electronics15081598
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Modeling and Calculation Method for Faults in the Distribution Network Connected to VSG-Type DGs

H. Oliver Gao, Hechong Chen, Fang Peng, Fan Yang et al.
Electronics
Microgrid Control and Optimization
article

A Modeling and Calculation Method for Faults in the Distribution Network Connected to VSG-Type DGs

H. Oliver Gao, Hechong Chen, Fang Peng, Fan Yang, Yang Lei, Wei Hu
article en

Abstract

Conventional fault analysis and calculation methods developed for synchronous-generator-dominated power systems exhibit limited applicability to distribution networks with high penetration of distributed generation (DG). These methods cannot provide a reliable theoretical basis for fault characteristic analysis or protection coordination. Existing studies on this scenario have primarily focused on the integration of grid-following (GFL) inverter-based resources (IBRs). By contrast, research on the integration of grid-forming (GFM) IBRs—particularly the virtual synchronous generator (VSG), which enables stable and sustainable utilization of renewable energy resources as synchronous generators—remains significantly inadequate. Therefore, this paper introduces a concise fault analysis and calculation method tailored to distribution networks with VSG-type DGs. First, the control strategy of the VSG-type DGs is examined, and the active-power response characteristics of VSG-type DGs are analyzed for faults in distribution networks. Equivalent models of a typical distribution network with VSG-type DGs are then established for symmetrical and asymmetrical faults. Subsequently, leveraging the active power–frequency and reactive power–voltage dependencies, a fault calculation method for distribution networks is proposed and its generality is examined. The method is convenient to implement and computationally efficient. It requires no detailed information on internal PI controller parameters or time constants of the control loops. PSCAD/EMTDC simulations are performed to verify the high accuracy and suitability of the proposed method for multi-DG scenarios, which facilitates the integration of VSG-type DGs in distribution networks.

ElectronicsVol. 15(8)
Shandong University (CN)
State Grid Corporation of China
Responsible consumption and production
Openalex Percentile: Top 17%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.