From vial to injector: Stability, degradation, and surface interactions of non-derivatized ecgonine methyl ester in GC–MS

Ecgonine methyl ester (EME) is a primary metabolite of cocaine widely used in forensic toxicology, yet it is often regarded as problematic for direct GC-MS analysis due to presumed thermal instability and surface-related losses. In this study, the stability of EME and its isotopically labeled analogue (EME-d₃) was systematically investigated under realistic laboratory conditions relevant to forensic workflows. Injector temperature, solvent composition, storage conditions, container material, evaporation steps, and matrix effects were evaluated using GC-MS. The results demonstrate that EME does not undergo significant thermal degradation during GC-MS injection, even at elevated injector temperatures, and that in-injector formation of anhydroecgonine methyl ester (AEME) is negligible. Instead, AEME formation arises predominantly from slow, solution-phase dehydration prior to injection, strongly influenced by solvent type, pH, vial material, and matrix composition. Methanol promoted degradation, whereas acetonitrile and mild acidification markedly improved stability. Biological matrices, particularly urine extracts, exerted a protective effect, suppressing dehydration during autosampler storage. A pronounced positive matrix effect was observed for EME in GC-MS, particularly in urine extracts, and was only partially compensated by the isotopically labeled internal standard. Adsorptive losses during evaporation were a major preanalytical issue: nearly quantitative in polypropylene and only partially mitigated by a keeper in glass vials. Overall, these findings show that the analytical challenges associated with EME are primarily preanalytical rather than instrumental. When appropriate handling strategies are applied, EME and EME-d₃ can be reliably quantified by GC-MS without derivatization, supporting their broader use in forensic toxicology.

Authors

Institutions

Publication Details

Journal
Journal of Chromatography B
Published
2026-04-13
DOI
https://doi.org/10.1016/j.jchromb.2026.125064
Primary Topic
Forensic Toxicology and Drug Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

From vial to injector: Stability, degradation, and surface interactions of non-derivatized ecgonine methyl ester in GC–MS

Inés Sánchez‐Sellero, Pamela Cabarcos-Fernández, Ana María Bermejo, Iván Álvarez-Freire et al.
Journal of Chromatography B
Forensic Toxicology and Drug Analysis
article

From vial to injector: Stability, degradation, and surface interactions of non-derivatized ecgonine methyl ester in GC–MS

Inés Sánchez‐Sellero, Pamela Cabarcos-Fernández, Ana María Bermejo, Iván Álvarez-Freire, N.C. Rubio, M.J. Tabernero-Duque
article en

Abstract

Ecgonine methyl ester (EME) is a primary metabolite of cocaine widely used in forensic toxicology, yet it is often regarded as problematic for direct GC-MS analysis due to presumed thermal instability and surface-related losses. In this study, the stability of EME and its isotopically labeled analogue (EME-d₃) was systematically investigated under realistic laboratory conditions relevant to forensic workflows. Injector temperature, solvent composition, storage conditions, container material, evaporation steps, and matrix effects were evaluated using GC-MS. The results demonstrate that EME does not undergo significant thermal degradation during GC-MS injection, even at elevated injector temperatures, and that in-injector formation of anhydroecgonine methyl ester (AEME) is negligible. Instead, AEME formation arises predominantly from slow, solution-phase dehydration prior to injection, strongly influenced by solvent type, pH, vial material, and matrix composition. Methanol promoted degradation, whereas acetonitrile and mild acidification markedly improved stability. Biological matrices, particularly urine extracts, exerted a protective effect, suppressing dehydration during autosampler storage. A pronounced positive matrix effect was observed for EME in GC-MS, particularly in urine extracts, and was only partially compensated by the isotopically labeled internal standard. Adsorptive losses during evaporation were a major preanalytical issue: nearly quantitative in polypropylene and only partially mitigated by a keeper in glass vials. Overall, these findings show that the analytical challenges associated with EME are primarily preanalytical rather than instrumental. When appropriate handling strategies are applied, EME and EME-d₃ can be reliably quantified by GC-MS without derivatization, supporting their broader use in forensic toxicology.

Journal of Chromatography BVol. 1277
Universidade de Santiago de Compostela (ES)
Openalex Percentile: Top 21%
Forensic Toxicology and Drug Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.