Three-year efficacy and safety of Revi® Implantable Tibial Neuromodulation from the pivotal OASIS Study

PURPOSE: Revi® is a novel implantable tibial neuromodulation (iTNM) system powered by an external, battery-operated wearable that facilitates individually tailored stimulation to provide treatment for urgency urinary incontinence (UUI). The Revi System (manufactured by BlueWind Medical) is the first FDA-cleared implantable neuromodulation device that can be used in traditionally non-refractory patients. Three-year follow-up results from the pivotal FDA-approval trial, the OASIS Study, are presented. MATERIALS AND METHODS: The Revi System was implanted in 151 women. The primary efficacy and safety endpoints were assessed at 6 and 12 months, respectively; thereafter, participants were consented to extend follow-up to 3 years for assessments of long-term treatment durability and safety. RESULTS: Ninety-three percent (140/151) completed the 12-month study and 85% (119/140) met screening criteria and consented to the 36-month extension study. Ninety participants (76%, (90/119) completed the 36-month assessment and 79% (71/90) were therapy responders (≥ 50% reduction in UUI episodes, demonstrated on a 3-day voiding diary). Sustained therapeutic responses were reported, with durable effectiveness between 6 and 36 months (response rates of 78% and 79%, respectively).Notably, 95% (83/87) reported therapeutic satisfaction and 82% (74/90) reported feeling "much better" or "very much better" based on the Patient Global Impression of Improvement (PGI-I) scale. No device- or procedure- related serious adverse events were reported through 36 months. CONCLUSIONS: In women with UUI, Revi - an iTNM system powered by a patient-controlled, external wearable ankle device - showed meaningful and durable efficacy, high patient satisfaction, and an excellent safety profile through 3 years.

Authors

Institutions

Publication Details

Journal
The Journal of Urology
Published
2026-04-13
DOI
https://doi.org/10.1097/ju.0000000000005062
Primary Topic
Pain Management and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Three-year efficacy and safety of Revi® Implantable Tibial Neuromodulation from the pivotal OASIS Study

John P.F.A. Heesakkers, Kevin Cline, Roger Roman Dmochowski, Peter R. Rodine et al.
The Journal of Urology
Pain Management and Treatment
article

Three-year efficacy and safety of Revi® Implantable Tibial Neuromodulation from the pivotal OASIS Study

John P.F.A. Heesakkers, Kevin Cline, Roger Roman Dmochowski, Peter R. Rodine, Frank Martens, Philip Toozs‐Hobson, Rebecca McCrery, Kevin Benson, Suzette E. Sutherland, C. Amundsen
article en

Abstract

PURPOSE: Revi® is a novel implantable tibial neuromodulation (iTNM) system powered by an external, battery-operated wearable that facilitates individually tailored stimulation to provide treatment for urgency urinary incontinence (UUI). The Revi System (manufactured by BlueWind Medical) is the first FDA-cleared implantable neuromodulation device that can be used in traditionally non-refractory patients. Three-year follow-up results from the pivotal FDA-approval trial, the OASIS Study, are presented. MATERIALS AND METHODS: The Revi System was implanted in 151 women. The primary efficacy and safety endpoints were assessed at 6 and 12 months, respectively; thereafter, participants were consented to extend follow-up to 3 years for assessments of long-term treatment durability and safety. RESULTS: Ninety-three percent (140/151) completed the 12-month study and 85% (119/140) met screening criteria and consented to the 36-month extension study. Ninety participants (76%, (90/119) completed the 36-month assessment and 79% (71/90) were therapy responders (≥ 50% reduction in UUI episodes, demonstrated on a 3-day voiding diary). Sustained therapeutic responses were reported, with durable effectiveness between 6 and 36 months (response rates of 78% and 79%, respectively).Notably, 95% (83/87) reported therapeutic satisfaction and 82% (74/90) reported feeling "much better" or "very much better" based on the Patient Global Impression of Improvement (PGI-I) scale. No device- or procedure- related serious adverse events were reported through 36 months. CONCLUSIONS: In women with UUI, Revi - an iTNM system powered by a patient-controlled, external wearable ankle device - showed meaningful and durable efficacy, high patient satisfaction, and an excellent safety profile through 3 years.

The Journal of Urology
Sanford Health (US), Radboud University Nijmegen (NL), Duke University (US), University of South Dakota (US), Louisiana State University in Shreveport (US), Maastricht University Medical Centre (NL), University Medical Center (US), Radboud University Medical Center (NL), University Hospital and Clinics (US), Arizona Pain Specialists (US), Birmingham Women’s and Children’s NHS Foundation Trust (GB), Pyrexar Medical (United States) (US), Adult and Pediatric Dermatology (US)
Openalex Percentile: Top 16%
Pain Management and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies