Feasibility and diagnostic performance of PETRA-MRA for postoperative follow-up of intracranial aneurysms: a prospective comparative study

Objective: Metal-related susceptibility artifacts have long limited the use of magnetic resonance angiography (MRA) for postoperative surveillance after intracranial aneurysm interventions. Pointwise encoding time reduction with radial acquisition (PETRA) substantially reduces metal-induced artifacts. This study aimed to evaluate the performance of PETRA-MRA in depicting parent artery image quality and aneurysm occlusion status at postoperative day 1 (T0) and 6 months (T1), and to explore its feasibility as a noninvasive alternative to digital subtraction angiography (DSA) for follow-up. Methods: In this prospective study, 100 patients harboring 100 intracranial aneurysms underwent time-of-flight MRA (TOF-MRA), PETRA-MRA, and DSA at both T0 and T1. Parent artery image quality was compared across time points and treatment modalities stent-assisted coiling (SAC) vs. flow diverter (FD) placement alone. A parsimonious cumulative logit regression model was performed to identify factors associated with PETRA-MRA image quality. Using DSA as the reference standard, the sensitivity, specificity, and accuracy of PETRA-MRA for assessing aneurysm occlusion were calculated. Results: Across both treatment groups, PETRA-MRA demonstrated significantly improved image quality at T1 compared with T0. At T1, both TOF-MRA and PETRA-MRA yielded higher image quality scores in the FD group than in the SAC group. Regression analysis indicated that none of the pre-specified covariates demonstrated a statistically significant independent association with PETRA-MRA image quality at T1 based on bootstrap-based inference. Complete occlusion rates increased markedly from T0 to T1: from 21.4% to 71.4% in the FD group and from 80.6% to 91.7% in the SAC group. Using DSA as the reference standard, PETRA-MRA demonstrated higher diagnostic accuracy than TOF-MRA at both time points in the SAC group, with accuracies of 94.44% in T0 and 97.67% in T1. Conclusion: PETRA-MRA demonstrates improved diagnostic performance at mid-term follow-up compared with the early postoperative period. Its marked ability to reduce metal artifacts and enhance visualization of both the parent artery and aneurysm lumen supports its potential as an effective, noninvasive alternative to DSA for long-term surveillance after intracranial aneurysm treatment.

Authors

Institutions

Publication Details

Journal
Frontiers in Neurology
Published
2026-04-13
DOI
https://doi.org/10.3389/fneur.2026.1786151
Primary Topic
Intracranial Aneurysms: Treatment and Complications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility and diagnostic performance of PETRA-MRA for postoperative follow-up of intracranial aneurysms: a prospective comparative study

Qin Jiang, Jinbing Zhao, Jun Hu, Xiao Wang
Frontiers in Neurology
Intracranial Aneurysms: Treatment and Complications
article

Feasibility and diagnostic performance of PETRA-MRA for postoperative follow-up of intracranial aneurysms: a prospective comparative study

Qin Jiang, Jinbing Zhao, Jun Hu, Xiao Wang
article en

Abstract

Objective: Metal-related susceptibility artifacts have long limited the use of magnetic resonance angiography (MRA) for postoperative surveillance after intracranial aneurysm interventions. Pointwise encoding time reduction with radial acquisition (PETRA) substantially reduces metal-induced artifacts. This study aimed to evaluate the performance of PETRA-MRA in depicting parent artery image quality and aneurysm occlusion status at postoperative day 1 (T0) and 6 months (T1), and to explore its feasibility as a noninvasive alternative to digital subtraction angiography (DSA) for follow-up. Methods: In this prospective study, 100 patients harboring 100 intracranial aneurysms underwent time-of-flight MRA (TOF-MRA), PETRA-MRA, and DSA at both T0 and T1. Parent artery image quality was compared across time points and treatment modalities stent-assisted coiling (SAC) vs. flow diverter (FD) placement alone. A parsimonious cumulative logit regression model was performed to identify factors associated with PETRA-MRA image quality. Using DSA as the reference standard, the sensitivity, specificity, and accuracy of PETRA-MRA for assessing aneurysm occlusion were calculated. Results: Across both treatment groups, PETRA-MRA demonstrated significantly improved image quality at T1 compared with T0. At T1, both TOF-MRA and PETRA-MRA yielded higher image quality scores in the FD group than in the SAC group. Regression analysis indicated that none of the pre-specified covariates demonstrated a statistically significant independent association with PETRA-MRA image quality at T1 based on bootstrap-based inference. Complete occlusion rates increased markedly from T0 to T1: from 21.4% to 71.4% in the FD group and from 80.6% to 91.7% in the SAC group. Using DSA as the reference standard, PETRA-MRA demonstrated higher diagnostic accuracy than TOF-MRA at both time points in the SAC group, with accuracies of 94.44% in T0 and 97.67% in T1. Conclusion: PETRA-MRA demonstrates improved diagnostic performance at mid-term follow-up compared with the early postoperative period. Its marked ability to reduce metal artifacts and enhance visualization of both the parent artery and aneurysm lumen supports its potential as an effective, noninvasive alternative to DSA for long-term surveillance after intracranial aneurysm treatment.

Frontiers in NeurologyVol. 17
Nanjing Brain Hospital (CN), Nanjing Medical University (CN)
Openalex Percentile: Top 23%
Intracranial Aneurysms: Treatment and Complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.