Virtual bone-implant contact surface effect on implant stability in fresh extraction and healed sites: a pilot randomised clinical trial

This study aimed to assess the effect of bone-implant contact surface area (BIC) on implant stability at fresh extraction sites without grafting, at simultaneous grafting, and at healed implant sites using a novel digital workflow that combines preoperative CBCT segmentation with postoperative intraoral scanning. A randomized controlled trial was conducted in 30 patients requiring dental implants in the upper premolar or molar regions. The patients were divided into three groups. Group I received immediate implant placement with grafts, Group II received immediate implant placement without grafts, and Group III followed the standard implant placement protocol for healed edentulous regions. All implants were placed by the same surgeon using the same implant system and the standard surgical protocol recommended by the manufacturer. In Group I, the residual gap was filled with a bone graft and covered with a membrane after implant placement. BIC and virtual non-contact surfaces (BINC) were calculated using digital registration. All results were compared among the groups based on insertion torque and ISQ values. The final analysis included 28 patients (10 males and 18 females). Group III showed better primary stability and insertion torque than the immediate placement groups (P = 0.014 and P = 0.007, respectively). There was no statistically significant difference between the implants placed Group I and Group II in terms of the insertion torque, or ISQ. The intraoperative ISQ value and the ISQ-60 days were strongly correlated with BIC only in Group II (r = 0.58, P = 0.05 and r = 0.62, P = 0.03, respectively). Group I and Group II lead to similar results regarding primary stability. Group III presented greater stability values. BIC served as a meaningful indicator of early mechanical stability in Group II.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-04-13
DOI
https://doi.org/10.1038/s41598-026-48697-8
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Virtual bone-implant contact surface effect on implant stability in fresh extraction and healed sites: a pilot randomised clinical trial

Ferit Bayram, Senem Aşkın Ekinci, Gökhan Göçmen, Sardar Fettahzade et al.
Scientific Reports
Dental Implant Techniques and Outcomes
article

Virtual bone-implant contact surface effect on implant stability in fresh extraction and healed sites: a pilot randomised clinical trial

Ferit Bayram, Senem Aşkın Ekinci, Gökhan Göçmen, Sardar Fettahzade, Yasar Ozkan
article en

Abstract

This study aimed to assess the effect of bone-implant contact surface area (BIC) on implant stability at fresh extraction sites without grafting, at simultaneous grafting, and at healed implant sites using a novel digital workflow that combines preoperative CBCT segmentation with postoperative intraoral scanning. A randomized controlled trial was conducted in 30 patients requiring dental implants in the upper premolar or molar regions. The patients were divided into three groups. Group I received immediate implant placement with grafts, Group II received immediate implant placement without grafts, and Group III followed the standard implant placement protocol for healed edentulous regions. All implants were placed by the same surgeon using the same implant system and the standard surgical protocol recommended by the manufacturer. In Group I, the residual gap was filled with a bone graft and covered with a membrane after implant placement. BIC and virtual non-contact surfaces (BINC) were calculated using digital registration. All results were compared among the groups based on insertion torque and ISQ values. The final analysis included 28 patients (10 males and 18 females). Group III showed better primary stability and insertion torque than the immediate placement groups (P = 0.014 and P = 0.007, respectively). There was no statistically significant difference between the implants placed Group I and Group II in terms of the insertion torque, or ISQ. The intraoperative ISQ value and the ISQ-60 days were strongly correlated with BIC only in Group II (r = 0.58, P = 0.05 and r = 0.62, P = 0.03, respectively). Group I and Group II lead to similar results regarding primary stability. Group III presented greater stability values. BIC served as a meaningful indicator of early mechanical stability in Group II.

Scientific Reports
Marmara University (TR)
Openalex Percentile: Top 16%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.