Subclavian chronic total occlusion angioplasty facilitates cardiac implantable electronic device upgrades: A single-center case series

Subclavian venous occlusion is a frequent complication of transvenous cardiac implantable electronic device (CIED) implantation, with reported incidences exceeding 30%. Although often asymptomatic, chronic total occlusion (CTO) creates a major technical barrier during device revision, particularly for cardiac resynchronization therapy (CRT) upgrades. Conventional strategies such as lead extraction or contralateral tunneling may increase procedural risk or compromise future vascular access. Subclavian CTO venoplasty is a minimally invasive alternative to re-establish ipsilateral access. We describe a single-center series of six patients (ages 62–78 years) who underwent percutaneous subclavian, axillary, or brachiocephalic venoplasty to facilitate CIED upgrade or lead revision. Our approach favored ipsilateral upper-extremity access (typically basilic vein) with a 0.018-inch platform using polymer-jacketed guidewires and microcatheters for CTO crossing. Serial balloon angioplasty (4.0–10.0 mm; 40–80 mm length range) was performed using stepwise inflation (nominal pressure with escalation as needed up to rated burst pressure per device specifications) to restore venous patency. Technical success was achieved in all six cases (100%), enabling four CRT implantations, one left bundle branch area pacing (LBBAP) implant, and one dual-chamber lead revision. No major intraprocedural complications occurred; one patient developed a self-resolving chest wall hematoma. Procedure time ranged from 116 to 240 min. Among CRT recipients, QRS duration narrowed (mean reduction 45 ± 18 ms). Follow-up (2–12 months) demonstrated stable lead parameters and no clinical evidence of recurrent occlusion. In this small series, subclavian/central venous CTO venoplasty using a brachial-first, 0.018-inch CTO-oriented strategy was feasible and enabled successful ipsilateral CIED revision while preserving vascular access. Larger studies are needed to better define the success rate and safety relative to the extraction or subclavian/device pocket access only approach.

Authors

Institutions

Publication Details

Journal
Journal of Interventional Cardiac Electrophysiology
Published
2026-04-13
DOI
https://doi.org/10.1007/s10840-026-02320-y
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Subclavian chronic total occlusion angioplasty facilitates cardiac implantable electronic device upgrades: A single-center case series

Sruti Prathivadhi-Bhayankaram, Sukit Ringwala, Xiarepati Tieliwaerdi, Emmanuel Olumuyide et al.
Journal of Interventional Cardiac Electrophysiology
Cardiac pacing and defibrillation studies
article

Subclavian chronic total occlusion angioplasty facilitates cardiac implantable electronic device upgrades: A single-center case series

Sruti Prathivadhi-Bhayankaram, Sukit Ringwala, Xiarepati Tieliwaerdi, Emmanuel Olumuyide, Joaquim Spadoni Barboza, Dana Johnson, Richard Amoateng
article en

Abstract

Subclavian venous occlusion is a frequent complication of transvenous cardiac implantable electronic device (CIED) implantation, with reported incidences exceeding 30%. Although often asymptomatic, chronic total occlusion (CTO) creates a major technical barrier during device revision, particularly for cardiac resynchronization therapy (CRT) upgrades. Conventional strategies such as lead extraction or contralateral tunneling may increase procedural risk or compromise future vascular access. Subclavian CTO venoplasty is a minimally invasive alternative to re-establish ipsilateral access. We describe a single-center series of six patients (ages 62–78 years) who underwent percutaneous subclavian, axillary, or brachiocephalic venoplasty to facilitate CIED upgrade or lead revision. Our approach favored ipsilateral upper-extremity access (typically basilic vein) with a 0.018-inch platform using polymer-jacketed guidewires and microcatheters for CTO crossing. Serial balloon angioplasty (4.0–10.0 mm; 40–80 mm length range) was performed using stepwise inflation (nominal pressure with escalation as needed up to rated burst pressure per device specifications) to restore venous patency. Technical success was achieved in all six cases (100%), enabling four CRT implantations, one left bundle branch area pacing (LBBAP) implant, and one dual-chamber lead revision. No major intraprocedural complications occurred; one patient developed a self-resolving chest wall hematoma. Procedure time ranged from 116 to 240 min. Among CRT recipients, QRS duration narrowed (mean reduction 45 ± 18 ms). Follow-up (2–12 months) demonstrated stable lead parameters and no clinical evidence of recurrent occlusion. In this small series, subclavian/central venous CTO venoplasty using a brachial-first, 0.018-inch CTO-oriented strategy was feasible and enabled successful ipsilateral CIED revision while preserving vascular access. Larger studies are needed to better define the success rate and safety relative to the extraction or subclavian/device pocket access only approach.

Journal of Interventional Cardiac Electrophysiology
Northwestern University (US), Illinois College (US), Allegheny General Hospital (US), University of Illinois Chicago (US), University of Chicago (US), Advocate Illinois Masonic Medical Center (US)
Openalex Percentile: Top 7%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.