Copper Nanocrystallization in Anodic Oxide Films of Ti–Cu‐Based Bulk Metallic Glass and Its Effect on the Corrosion Resistance and Cytocompatibility

This study investigates anodic surface modification of the Ti 47 Cu 38 Zr 7.5 Fe 2.5 Sn 2 Si 1 Ag 2 bulk metallic glass in a nontoxic potassium pyrophosphate electrolyte and its impact on corrosion behavior and cytocompatibility. The treatment forms bilayered oxide films (20–90 nm) via selective Cu dealloying and Ti/Zr oxide formation. Analyses by transmission electron microscopy and glow discharge optical emission spectroscopy reveal a dense inner amorphous layer and a porous outer layer containing metallic Cu nanocrystals, formed through Cu mobilization and reduction. Electrochemical testing demonstrates that anodization at 1.3 V vs. saturated mercury sulfate electrode significantly enhances corrosion resistance in chloride‐containing phosphate‐buffered saline and reduces Cu ion release by approximately 50% compared to the untreated state. Contact angle measurements confirm increased surface hydrophilicity due to the Ti/Zr oxide matrix. Biological evaluation shows that this optimized surface promotes human bone marrow stromal cell spreading and focal adhesion formation. It results in a 4.5‐fold increase in cell proliferation and elevated activity of the osteogenic marker tissue nonspecific alkaline phosphatase, indicating enhanced osteogenic differentiation. These findings highlight that controlled anodization in a nontoxic pyrophosphate electrolyte can tailor surface oxide structure and composition, simultaneously improving corrosion resistance, cytocompatibility of Ti–Cu‐based metallic glasses for advanced biomedical implants.

Authors

Institutions

Publication Details

Journal
Advanced Engineering Materials
Published
2026-04-13
DOI
https://doi.org/10.1002/adem.70774
Primary Topic
Nanoporous metals and alloys
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Copper Nanocrystallization in Anodic Oxide Films of Ti–Cu‐Based Bulk Metallic Glass and Its Effect on the Corrosion Resistance and Cytocompatibility

Ute Hempel, Viktoriia Shtefan, Nora Fernández Navas, V. Hoffmann et al.
Advanced Engineering Materials
Nanoporous metals and alloys
article

Copper Nanocrystallization in Anodic Oxide Films of Ti–Cu‐Based Bulk Metallic Glass and Its Effect on the Corrosion Resistance and Cytocompatibility

Ute Hempel, Viktoriia Shtefan, Nora Fernández Navas, V. Hoffmann, Thorgund Nemec, Andrea Voß, D. Pohl, I. Kaban, Annett Gebert
article en

Abstract

This study investigates anodic surface modification of the Ti 47 Cu 38 Zr 7.5 Fe 2.5 Sn 2 Si 1 Ag 2 bulk metallic glass in a nontoxic potassium pyrophosphate electrolyte and its impact on corrosion behavior and cytocompatibility. The treatment forms bilayered oxide films (20–90 nm) via selective Cu dealloying and Ti/Zr oxide formation. Analyses by transmission electron microscopy and glow discharge optical emission spectroscopy reveal a dense inner amorphous layer and a porous outer layer containing metallic Cu nanocrystals, formed through Cu mobilization and reduction. Electrochemical testing demonstrates that anodization at 1.3 V vs. saturated mercury sulfate electrode significantly enhances corrosion resistance in chloride‐containing phosphate‐buffered saline and reduces Cu ion release by approximately 50% compared to the untreated state. Contact angle measurements confirm increased surface hydrophilicity due to the Ti/Zr oxide matrix. Biological evaluation shows that this optimized surface promotes human bone marrow stromal cell spreading and focal adhesion formation. It results in a 4.5‐fold increase in cell proliferation and elevated activity of the osteogenic marker tissue nonspecific alkaline phosphatase, indicating enhanced osteogenic differentiation. These findings highlight that controlled anodization in a nontoxic pyrophosphate electrolyte can tailor surface oxide structure and composition, simultaneously improving corrosion resistance, cytocompatibility of Ti–Cu‐based metallic glasses for advanced biomedical implants.

Advanced Engineering Materials
Leibniz Institute for Solid State and Materials Research (DE), Center for Systems Biology Dresden (DE), University Hospital Carl Gustav Carus (DE), Hochschule für Technik und Wirtschaft Dresden – University of Applied Sciences (DE), National Technical University "Kharkiv Polytechnic Institute" (UA), Technische Universität Dresden (DE)
Deutsche Forschungsgemeinschaft
Openalex Percentile: Top 21%
Nanoporous metals and alloys
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.