Real-time intraoperative motion-following robotic assistance improves efficiency and accuracy in total knee arthroplasty: a retrospective comparative study

BACKGROUND: Conventional robotic-assisted total knee arthroplasty (RA-TKA) relies on rigid limb fixation to suppress intra-operative motion, adding complexity and potential inefficiency. A novel motion-following control system dynamically compensates for limb movement, allowing real-time adjustment of the tool-bone relationship without immobilization. This study evaluated whether motion-following improves efficiency and osteotomy accuracy while preserving alignment and early function. METHODS: Sixty consecutive primary RA-TKA cases performed with the SkyWalker robotic platform (MicroPort, Shanghai, China) between September 2022 and August 2024 were retrospectively reviewed. Thirty procedures used conventional rigid fixation (control group) and thirty employed motion-following tracking (motion-Following group). Primary endpoints were operative time and resection thickness error, measured intraoperatively with a caliper. Secondary outcomes included coronal alignment assessed by HKA (hip-knee-ankle angle), CFCA (coronal femoral component angle), and CTCA (coronal tibial component angle), as well as functional recovery assessed by WOMAC (Western Ontario and McMaster Universities Osteoarthritis Index) at 6 months. Values are expressed as mean ± standard deviation unless otherwise specified. RESULTS: Mean operative time was shorter with motion-following (118.8 ± 9.3 min) than with conventional fixation (133.9 ± 11.9 min; p < 0.001). Mean resection-thickness error was lower with motion-following (0.53 mm vs 0.82 mm), with 93.9% versus 68.3% of cuts within ≤ 1 mm. At the plane level, motion-following achieved smaller errors on all six surfaces, with four planes: DF-M (distal femur medial), distal femur lateral (DF-L), posterior femur medial (PF-M), and tibial plateau lateral (TP-L) reaching statistical significance (p < 0.05). Post-operative coronal alignment closely reproduced the pre-operative plan in both groups, with mean deviations of approximately 1° across all parameters and no statistically significant between-group differences. WOMAC scores improved substantially in both groups, with no significant between-group difference (ΔWOMAC 32.8 ± 8.5 vs 30.1 ± 7.9; p = 0.21). CONCLUSIONS: Motion-following robotic control streamlines TKA by eliminating rigid fixation, improving workflow efficiency, and slightly enhancing osteotomy precision without compromising alignment or recovery. This dynamic, real-time tracking approach refines execution of the surgical plan and may represent a meaningful evolution toward more efficient, surgeon-friendly robotic arthroplasty.

Authors

Institutions

Publication Details

Journal
Arthroplasty
Published
2026-04-14
DOI
https://doi.org/10.1186/s42836-026-00384-9
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-time intraoperative motion-following robotic assistance improves efficiency and accuracy in total knee arthroplasty: a retrospective comparative study

ZHAI Zanjing, Huiwu Li, Zhuwen Xu, Zihan Li et al.
Arthroplasty
Total Knee Arthroplasty Outcomes
article

Real-time intraoperative motion-following robotic assistance improves efficiency and accuracy in total knee arthroplasty: a retrospective comparative study

ZHAI Zanjing, Huiwu Li, Zhuwen Xu, Zihan Li, Dajiang Li, Hui Shao, Keyu Kong
article en

Abstract

BACKGROUND: Conventional robotic-assisted total knee arthroplasty (RA-TKA) relies on rigid limb fixation to suppress intra-operative motion, adding complexity and potential inefficiency. A novel motion-following control system dynamically compensates for limb movement, allowing real-time adjustment of the tool-bone relationship without immobilization. This study evaluated whether motion-following improves efficiency and osteotomy accuracy while preserving alignment and early function. METHODS: Sixty consecutive primary RA-TKA cases performed with the SkyWalker robotic platform (MicroPort, Shanghai, China) between September 2022 and August 2024 were retrospectively reviewed. Thirty procedures used conventional rigid fixation (control group) and thirty employed motion-following tracking (motion-Following group). Primary endpoints were operative time and resection thickness error, measured intraoperatively with a caliper. Secondary outcomes included coronal alignment assessed by HKA (hip-knee-ankle angle), CFCA (coronal femoral component angle), and CTCA (coronal tibial component angle), as well as functional recovery assessed by WOMAC (Western Ontario and McMaster Universities Osteoarthritis Index) at 6 months. Values are expressed as mean ± standard deviation unless otherwise specified. RESULTS: Mean operative time was shorter with motion-following (118.8 ± 9.3 min) than with conventional fixation (133.9 ± 11.9 min; p < 0.001). Mean resection-thickness error was lower with motion-following (0.53 mm vs 0.82 mm), with 93.9% versus 68.3% of cuts within ≤ 1 mm. At the plane level, motion-following achieved smaller errors on all six surfaces, with four planes: DF-M (distal femur medial), distal femur lateral (DF-L), posterior femur medial (PF-M), and tibial plateau lateral (TP-L) reaching statistical significance (p < 0.05). Post-operative coronal alignment closely reproduced the pre-operative plan in both groups, with mean deviations of approximately 1° across all parameters and no statistically significant between-group differences. WOMAC scores improved substantially in both groups, with no significant between-group difference (ΔWOMAC 32.8 ± 8.5 vs 30.1 ± 7.9; p = 0.21). CONCLUSIONS: Motion-following robotic control streamlines TKA by eliminating rigid fixation, improving workflow efficiency, and slightly enhancing osteotomy precision without compromising alignment or recovery. This dynamic, real-time tracking approach refines execution of the surgical plan and may represent a meaningful evolution toward more efficient, surgeon-friendly robotic arthroplasty.

ArthroplastyVol. 8(1)
Shanghai Jiao Tong University (CN), MicroPort (China) (CN), Shanghai Ninth People's Hospital (CN), People's Hospital of Shiyan (CN), MEMS RIGHT (China) (CN)
National Natural Science Foundation of China, Shanghai Municipal Education Commission, Fundamental Research Funds for the Central Universities
Openalex Percentile: Top 28%
Total Knee Arthroplasty Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.