Performance of CT-guided spatial normalization for semi-quantification of dopamine transporter SPECT and detection of nigrostriatal degeneration
The present study aims to assess the performance of a CT-guided spatial normalization method (CT-method) for the anatomical region-of-interest (ROI)-based semi-quantification of dopamine transporter (DAT) single photon emission computed tomography (SPECT) images and the detection of nigrostriatal degeneration as compared to an effective SPECT template-based method (MSPECT-method) and visual analysis performed by an expert reader. Patients who underwent [123I]FP-CIT SPECT/CT in the Hospices Civils de Lyon between 2008 and 2018 for clinically uncertain parkinsonian syndromes were included. The proposed CT-method aimed to spatially normalize the jointly acquired CT scans and apply the deformation fields to the coregistered SPECT images. It was compared to an effective SPECT template-based method using multiple templates as target for the spatial normalization (MSPECT-method). The distribution of specific binding ratios (SBR) was compared between both methods and the SBR classifications were compared to an expert’s visual classification of the scans, which served as the reference. Overall, 1156 patients (mean age ± SD = 68.7 ± 11.5; 52.6% male) were included. The CT-method provided a good separation between the normal and reduced SBR, with a higher effect size of the distance between the Gaussians (3.31 vs 3.11) and smaller overlap (6.44% vs 8.96%) compared to the MSPECT-method. Both the CT-method and MSPECT-method demonstrated high classification accuracy (96.7%, 95% CI: 95.7-97.7% vs. 94.6%, 95% CI: 93.3-95.9%), sensitivity (96.0%, CI: 94.3-97.7% vs. 89.7%, CI: 87.1-92.3%), and specificity (97.3%, CI: 96.1-98.6% vs. 98.7%, CI: 97.9-99.6%), respectively. The proposed CT-guided spatial normalization method for automated semi-quantitative [123I]FP-CIT SPECT analysis is a viable option when CT images are available. It offers objective spatial normalization and provides high accuracy for the detection of nigrostriatal degeneration, closely aligning with an expert’s visual interpretation.
Authors
- Anthime Flaus (ORCID: https://orcid.org/0000-0001-5877-2159)
- Thomas Grenier (ORCID: https://orcid.org/0000-0002-3630-5856)
- Ralph Buchert (ORCID: https://orcid.org/0000-0002-0945-0724)
- C. Scheiber
- Alae Eddine El Barkaoui
- Marc Janier
- Stephane Thobois
Institutions
- Université Claude Bernard Lyon 1 (FR)
- Centre National de la Recherche Scientifique (FR)
- Inserm (FR)
- Universität Hamburg (DE)
- Centre de Recherche en Neurosciences de Lyon (FR)
- Hospices Civils de Lyon (FR)
- Hôpital Pierre Wertheimer (FR)
- University Medical Center Hamburg-Eppendorf (DE)
- Laboratoire d'Automatique, de Génie des Procédés et de Génie Pharmaceutique (FR)
- Institut des Sciences Cognitives (FR)
- Institut National des Sciences Appliquées de Lyon (FR)
Publication Details
- Journal
- Annals of Nuclear Medicine
- Published
- 2026-04-13
- DOI
- https://doi.org/10.1007/s12149-026-02204-1
- Primary Topic
- Parkinson's Disease Mechanisms and Treatments
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Hospices Civils de Lyon