Comparative evaluation of compressive strength of CAD-CAM polyetheretherketone and indirect composite Class II inlays: an in vitro study

Polyetheretherketone (PEEK) is a high-performance thermoplastic polymer that is currently being utilized in the dental field due to its desirable mechanical characteristics, biocompatibility, and ease of integration into digital CAD-CAM processes. Despite the esthetic and esthetic benefits of composite resins in Class II inlays, mechanical performance in high-stress posterior restorations continues to be a clinical issue with the material. Although other research has been conducted to utilize PEEK in different dental treatment procedures, there are no direct comparative studies dealing specifically with the compressive strength of Class II dental restorations using CAD-CAM developed PEEK inlays as compared to indirect composite inlays. This study aimed to compare the compressive strength of PEEK and composite resin when used as Class II inlays and evaluate PEEK's suitability as an alternative restorative material. Thirty-four human premolars extracted for orthodontic reasons and randomly allocated to two groups (n = 17). Group A was provided with CAD-CAM-produced PEEK inlays, and Group B was restored with inlays made of an indirect composite. Fracture load testing of all specimens was done through a universal testing machine. An independent t -test was used to statistically analyze the compressive strength values. The PEEK group showed a mean compressive strength value of 381.88 N compared to 266.67 N in the composite group, and the p-value was below 0.001, which was a statistically significant difference. PEEK inlays proved to have better compressive strength than composite resin inlays, which implies that PEEK is a prospective Class II restorative material in stress-bearing posterior areas. Its clinical performance over the long term and in more applications should be the subject of future research.

Authors

Institutions

Publication Details

Journal
The Saudi Dental Journal
Published
2026-04-01
DOI
https://doi.org/10.1007/s44445-026-00150-2
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative evaluation of compressive strength of CAD-CAM polyetheretherketone and indirect composite Class II inlays: an in vitro study

Nikita Poonia, Nidhi Sharma, Diksha Yadav, Ish Sharma et al.
The Saudi Dental Journal
Dental materials and restorations
article

Comparative evaluation of compressive strength of CAD-CAM polyetheretherketone and indirect composite Class II inlays: an in vitro study

Nikita Poonia, Nidhi Sharma, Diksha Yadav, Ish Sharma, Neha Verma, Siddhant Mahajan
article en

Abstract

Polyetheretherketone (PEEK) is a high-performance thermoplastic polymer that is currently being utilized in the dental field due to its desirable mechanical characteristics, biocompatibility, and ease of integration into digital CAD-CAM processes. Despite the esthetic and esthetic benefits of composite resins in Class II inlays, mechanical performance in high-stress posterior restorations continues to be a clinical issue with the material. Although other research has been conducted to utilize PEEK in different dental treatment procedures, there are no direct comparative studies dealing specifically with the compressive strength of Class II dental restorations using CAD-CAM developed PEEK inlays as compared to indirect composite inlays. This study aimed to compare the compressive strength of PEEK and composite resin when used as Class II inlays and evaluate PEEK's suitability as an alternative restorative material. Thirty-four human premolars extracted for orthodontic reasons and randomly allocated to two groups (n = 17). Group A was provided with CAD-CAM-produced PEEK inlays, and Group B was restored with inlays made of an indirect composite. Fracture load testing of all specimens was done through a universal testing machine. An independent t -test was used to statistically analyze the compressive strength values. The PEEK group showed a mean compressive strength value of 381.88 N compared to 266.67 N in the composite group, and the p-value was below 0.001, which was a statistically significant difference. PEEK inlays proved to have better compressive strength than composite resin inlays, which implies that PEEK is a prospective Class II restorative material in stress-bearing posterior areas. Its clinical performance over the long term and in more applications should be the subject of future research.

The Saudi Dental JournalVol. 38(4)
Dabur Research Foundation (India) (IN)
Openalex Percentile: Top 25%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparative evaluation of compressive strength of CAD-CAM polyetheretherketone and indirect composite Class II inlays: an in vitro study — Nikita Poonia, Nidhi Sharma, et al. · The Saudi Dental Journal (2026) | TGRS Research Map | TGRS