Intra-operative fluoroscopic measurement accuracy for femoral tunnel aperture positions in anterior cruciate ligament reconstruction

This study aimed to test an automated analysis software for the three-dimensional (3D) quadrant method and assess the accuracy of femoral tunnel positioning during double-bundle anterior cruciate ligament reconstruction (DB-ACLR) with fluoroscopic assistance versus conventional 3D computed tomography (3D-CT). We retrospectively evaluated 32 patients who underwent DB-ACLR between 2010 and 2014. The femoral tunnel location was calculated using three methods: the quadrant fluoroscopy method, the (modified) quadrant method using conventional 3D-CT, and the automated 3D reconstruction method. Two independent observers assessed each knee position. The accuracy of tunnel location on the fluoroscopic radiograph and conventional 3D-CT was compared to the automated 3D reconstruction method. Femoral tunnel locations measured by the quadrant method using an automated 3D reconstruction method were 19.1 ± 4.8 % of depth and 22.3 ± 7.7 % of height in anteromedial (AM) femoral tunnels, 32.2 ± 6.0% of depth and 48.4 ± 7.7% of height in posterolateral (PL) tunnels. Using fluoroscopy, 20.3 ± 5.0 % of depth and 26.8 ± 8.9 % of height in AM tunnels, and 32.9 ± 5.4% of depth and 50.6 ± 7.9% of height in PL tunnels was achieved. Using conventional 3D CT, 21.3 ± 4.6 % of depth and 26.0 ± 9.1 % of height in AM tunnels, and 34.9 ± 7.1% of depth and 50.1 ± 8.0% of height in PL tunnels was achieved. When analyzed using the Bland-Altman plot, the Limit of Agreement (LOA) in the fluoroscopy group was closer to the equator than conventional 3D CT group in all cases, except for the height of the AM tunnel, which had a slightly lower LOA. The fluoroscopically identified tunnel aperture location was more accurate and reproducible than the one obtained via the quadrant method using conventional 3D-CT imaging. IV This study showed the femoral tunnel position on the fluoroscopic image is close to real position in 3D femoral image, Therefore, intraoperative fluoroscopy is can be applied as a feasible method for improving the accuracy of anatomical tunnel positioning.

Authors

Institutions

Publication Details

Journal
BMC Musculoskeletal Disorders
Published
2026-04-13
DOI
https://doi.org/10.1186/s12891-026-09606-2
Primary Topic
Knee injuries and reconstruction techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Intra-operative fluoroscopic measurement accuracy for femoral tunnel aperture positions in anterior cruciate ligament reconstruction

Youngchang Kim, B. K. Lee, Jae Ang Sim, Seong Hyup Ham et al.
BMC Musculoskeletal Disorders
Knee injuries and reconstruction techniques
article

Intra-operative fluoroscopic measurement accuracy for femoral tunnel aperture positions in anterior cruciate ligament reconstruction

Youngchang Kim, B. K. Lee, Jae Ang Sim, Seong Hyup Ham, Jung Min Shin
article en

Abstract

This study aimed to test an automated analysis software for the three-dimensional (3D) quadrant method and assess the accuracy of femoral tunnel positioning during double-bundle anterior cruciate ligament reconstruction (DB-ACLR) with fluoroscopic assistance versus conventional 3D computed tomography (3D-CT). We retrospectively evaluated 32 patients who underwent DB-ACLR between 2010 and 2014. The femoral tunnel location was calculated using three methods: the quadrant fluoroscopy method, the (modified) quadrant method using conventional 3D-CT, and the automated 3D reconstruction method. Two independent observers assessed each knee position. The accuracy of tunnel location on the fluoroscopic radiograph and conventional 3D-CT was compared to the automated 3D reconstruction method. Femoral tunnel locations measured by the quadrant method using an automated 3D reconstruction method were 19.1 ± 4.8 % of depth and 22.3 ± 7.7 % of height in anteromedial (AM) femoral tunnels, 32.2 ± 6.0% of depth and 48.4 ± 7.7% of height in posterolateral (PL) tunnels. Using fluoroscopy, 20.3 ± 5.0 % of depth and 26.8 ± 8.9 % of height in AM tunnels, and 32.9 ± 5.4% of depth and 50.6 ± 7.9% of height in PL tunnels was achieved. Using conventional 3D CT, 21.3 ± 4.6 % of depth and 26.0 ± 9.1 % of height in AM tunnels, and 34.9 ± 7.1% of depth and 50.1 ± 8.0% of height in PL tunnels was achieved. When analyzed using the Bland-Altman plot, the Limit of Agreement (LOA) in the fluoroscopy group was closer to the equator than conventional 3D CT group in all cases, except for the height of the AM tunnel, which had a slightly lower LOA. The fluoroscopically identified tunnel aperture location was more accurate and reproducible than the one obtained via the quadrant method using conventional 3D-CT imaging. IV This study showed the femoral tunnel position on the fluoroscopic image is close to real position in 3D femoral image, Therefore, intraoperative fluoroscopy is can be applied as a feasible method for improving the accuracy of anatomical tunnel positioning.

BMC Musculoskeletal Disorders
Eulji University (KR), Gachon University Gil Medical Center (KR), Korea Institute of Science and Technology (KR)
Openalex Percentile: Top 8%
Knee injuries and reconstruction techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.