Pilot study using synthetic MRI for determining the disease activity of thyroid-associated ophthalmopathy

OBJECTIVE: To investigate the value of synthetic magnetic resonance imaging (SyMRI) of extraocular muscles (EOMs) in determining the disease activity of thyroid-associated ophthalmopathy (TAO). METHODS: Seventy-seven patients with TAO (31 active; 46 inactive) were prospectively enrolled. Orbital SyMRI was performed and post-processed to generate quantitative maps (T1 map, T2 map, and proton density [PD] map) and contrast-weighted images (double inversion recovery [DIR], short inversion recovery [STIR], and fluid-attenuated inversion recovery [FLAIR]). Maximum, mean, and minimum values of PD, T1 relaxation time (T1RT), and T2 relaxation time (T2RT) of EOMs, and the signal intensity ratio (SIR) of contrast-weighted images were calculated and compared between two groups. Multivariate logistic regression identified independent predictors of disease activity. Receiver operating characteristic curve analyses and DeLong tests evaluated and compared the diagnostic performance of significant parameters and combined models. RESULTS: Active TAO patients had higher values of both quantitative and semi-quantitative parameters than inactive patients, except for FLAIR-Min (all p < 0.05). DIR-Mean, PD-Mean, T1RT-Mean, and T2RT-Mean of EOMs were independently associated with active TAO (all p < 0.05). The combined model integrating four independent predictors showed higher diagnostic performance (AUC, 0.884; specificity, 89.13%; sensitivity, 77.42%) than DIR-Mean (AUC=0.802), PD-Mean (AUC=0.818), T1RT-Mean (AUC=0.835), or T2RT-Mean (AUC=0.824) alone in distinguishing active from inactive patients (all p < 0.05). CONCLUSION: SyMRI might be one promising imaging modality for determining the disease activity of TAO. ADVANCES IN KNOWLEDGE:: SyMRI quantifies PD, T1RT, and T2RT in a single scan with clinically acceptable time. Our study innovatively synthesized multiple contrast-weighted images, improving the efficacy of TAO staging.

Authors

Institutions

Publication Details

Journal
British Journal of Radiology
Published
2026-04-11
DOI
https://doi.org/10.1093/bjr/tqag082
Primary Topic
Ophthalmology and Eye Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pilot study using synthetic MRI for determining the disease activity of thyroid-associated ophthalmopathy

Jinling Lu, Xiao‐Quan Xu, Ying Wan, Hao Hu et al.
British Journal of Radiology
Ophthalmology and Eye Disorders
article

Pilot study using synthetic MRI for determining the disease activity of thyroid-associated ophthalmopathy

Jinling Lu, Xiao‐Quan Xu, Ying Wan, Hao Hu, Fei-Yun Wu, Jiang Zhou, Huan-Huan Chen, Yu-Hui Zhou
article en

Abstract

OBJECTIVE: To investigate the value of synthetic magnetic resonance imaging (SyMRI) of extraocular muscles (EOMs) in determining the disease activity of thyroid-associated ophthalmopathy (TAO). METHODS: Seventy-seven patients with TAO (31 active; 46 inactive) were prospectively enrolled. Orbital SyMRI was performed and post-processed to generate quantitative maps (T1 map, T2 map, and proton density [PD] map) and contrast-weighted images (double inversion recovery [DIR], short inversion recovery [STIR], and fluid-attenuated inversion recovery [FLAIR]). Maximum, mean, and minimum values of PD, T1 relaxation time (T1RT), and T2 relaxation time (T2RT) of EOMs, and the signal intensity ratio (SIR) of contrast-weighted images were calculated and compared between two groups. Multivariate logistic regression identified independent predictors of disease activity. Receiver operating characteristic curve analyses and DeLong tests evaluated and compared the diagnostic performance of significant parameters and combined models. RESULTS: Active TAO patients had higher values of both quantitative and semi-quantitative parameters than inactive patients, except for FLAIR-Min (all p < 0.05). DIR-Mean, PD-Mean, T1RT-Mean, and T2RT-Mean of EOMs were independently associated with active TAO (all p < 0.05). The combined model integrating four independent predictors showed higher diagnostic performance (AUC, 0.884; specificity, 89.13%; sensitivity, 77.42%) than DIR-Mean (AUC=0.802), PD-Mean (AUC=0.818), T1RT-Mean (AUC=0.835), or T2RT-Mean (AUC=0.824) alone in distinguishing active from inactive patients (all p < 0.05). CONCLUSION: SyMRI might be one promising imaging modality for determining the disease activity of TAO. ADVANCES IN KNOWLEDGE:: SyMRI quantifies PD, T1RT, and T2RT in a single scan with clinically acceptable time. Our study innovatively synthesized multiple contrast-weighted images, improving the efficacy of TAO staging.

British Journal of Radiology
Nanjing Medical University (CN)
Openalex Percentile: Top 27%
Ophthalmology and Eye Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.