Impact of deep learning image reconstruction on ADC quantification and histogram metrics: a phantom study

OBJECTIVE: Recently, deep learning (DL)-based reconstruction methods have been introduced into clinical magnetic resonance imaging (MRI) systems to enhance image quality and reduce acquisition time. However, their effects on apparent diffusion coefficient (ADC) maps remain unclear. We investigated whether DL-based image reconstruction influences ADC quantification and histogram-based ADC metrics using a calibrated diffusion-weighted imaging (DWI) phantom. MATERIALS AND METHODS: A phantom containing vials with known ADC values was scanned on a 3-T system using full (fFOV) and reduced (rFOV) field-of-view DWI sequences. Each acquisition was performed using conventional (DL-OFF) and three DL-based strength levels (low, medium, high). Median ADC values were analyzed for repeatability (coefficient of variation (CV)) and accuracy. Histogram changes and first-order radiomic features were assessed using the Wasserstein distance, Friedman, and Wilcoxon tests. RESULTS: ADC estimates showed high repeatability (CV 0.1-1.2%) and good accuracy (deviation -2 to 7%) across all DL levels and sequences. DL reconstruction progressively reduced histogram dispersion, particularly in high-ADC vials. Wasserstein distances increased with DL strength, confirming a progressive effect on ADC value distributions, while median ADC values remained unchanged. Entropy and interquartile range decreased significantly (p < 0.001), whereas kurtosis and skewness increased, with differences showing less stable and sequence-dependent statistical significance. CONCLUSION: DL-based reconstruction maintained accurate and repeatable ADC quantification while reducing the dispersion of ADC values. The effect was more evident for high-ADC regions and the rFOV sequence, resulting in narrower distributions of ADC values. Further investigations comparing different DL-based solutions are warranted to assess the generalizability of these findings in clinical settings. RELEVANCE STATEMENT: Over the past decade, ADC histogram analysis has proven valuable for quantifying tumor heterogeneity, differentiating tumor grade, and evaluating early treatment response. Deep learning reconstruction narrows ADC distributions and reduces dispersion, supporting its potential in oncologic DWI, while highlighting the need for patient-based validation studies. KEY POINTS: DL reconstruction preserved ADC accuracy in both full FOV and reduced FOV DWI. ADC repeatability remained high across DL levels for both DWI sequences. Histogram dispersion progressively reduced across DL levels, particularly in high-ADC vials. Entropy and interquartile ranges decreased progressively with increasing DL strength.

Authors

Institutions

Publication Details

Journal
European Radiology Experimental
Published
2026-04-13
DOI
https://doi.org/10.1186/s41747-026-00709-y
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of deep learning image reconstruction on ADC quantification and histogram metrics: a phantom study

Vicente Bruzzaniti, Simona Marzi, Antonello Vidiri, Roberto Castellana et al.
European Radiology Experimental
Medical Imaging Techniques and Applications
article

Impact of deep learning image reconstruction on ADC quantification and histogram metrics: a phantom study

Vicente Bruzzaniti, Simona Marzi, Antonello Vidiri, Roberto Castellana, A. Tonnetti, Irene Terrenato, G. Di Giulio, Francesca Laganaro, Michele Farella
article en

Abstract

OBJECTIVE: Recently, deep learning (DL)-based reconstruction methods have been introduced into clinical magnetic resonance imaging (MRI) systems to enhance image quality and reduce acquisition time. However, their effects on apparent diffusion coefficient (ADC) maps remain unclear. We investigated whether DL-based image reconstruction influences ADC quantification and histogram-based ADC metrics using a calibrated diffusion-weighted imaging (DWI) phantom. MATERIALS AND METHODS: A phantom containing vials with known ADC values was scanned on a 3-T system using full (fFOV) and reduced (rFOV) field-of-view DWI sequences. Each acquisition was performed using conventional (DL-OFF) and three DL-based strength levels (low, medium, high). Median ADC values were analyzed for repeatability (coefficient of variation (CV)) and accuracy. Histogram changes and first-order radiomic features were assessed using the Wasserstein distance, Friedman, and Wilcoxon tests. RESULTS: ADC estimates showed high repeatability (CV 0.1-1.2%) and good accuracy (deviation -2 to 7%) across all DL levels and sequences. DL reconstruction progressively reduced histogram dispersion, particularly in high-ADC vials. Wasserstein distances increased with DL strength, confirming a progressive effect on ADC value distributions, while median ADC values remained unchanged. Entropy and interquartile range decreased significantly (p < 0.001), whereas kurtosis and skewness increased, with differences showing less stable and sequence-dependent statistical significance. CONCLUSION: DL-based reconstruction maintained accurate and repeatable ADC quantification while reducing the dispersion of ADC values. The effect was more evident for high-ADC regions and the rFOV sequence, resulting in narrower distributions of ADC values. Further investigations comparing different DL-based solutions are warranted to assess the generalizability of these findings in clinical settings. RELEVANCE STATEMENT: Over the past decade, ADC histogram analysis has proven valuable for quantifying tumor heterogeneity, differentiating tumor grade, and evaluating early treatment response. Deep learning reconstruction narrows ADC distributions and reduces dispersion, supporting its potential in oncologic DWI, while highlighting the need for patient-based validation studies. KEY POINTS: DL reconstruction preserved ADC accuracy in both full FOV and reduced FOV DWI. ADC repeatability remained high across DL levels for both DWI sequences. Histogram dispersion progressively reduced across DL levels, particularly in high-ADC vials. Entropy and interquartile ranges decreased progressively with increasing DL strength.

European Radiology ExperimentalVol. 10(1)
National Cancer Institute (MY), Istituti di Ricovero e Cura a Carattere Scientifico (IT)
Ministero della Salute
Openalex Percentile: Top 22%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.