Clinical performance of low-shrinkage giomer compared to nanohybrid resin composite in proximal restorations after one year: a randomized clinical trial

OBJECTIVES: The present study assesses the clinical performance and occlusal wear of low-shrinkage giomer and nanohybrid composite in proximal restorations. METHODS: Fifty participants with proximal caries in posterior teeth (n = 25) were recruited. Teeth were restored with either conventional nano-hybrid composite (Filtek Z250XT, 3M ESPE, USA) or low-shrinkage giomer (Beautifil II LS, Shofu Inc, Japan). Clinical performance was assessed using revised FDI criteria at baseline, 6 and 12 months. Wear was assessed after 12 months by using 3D inspection and metrology software (Geomagic Control X; 3D Systems, USA). FDI scores were analyzed using Chi‑square test for intergroup comparisons and Cochran's Q‑test for intragroup comparisons. Wear data were analyzed using independent t test for intergroup comparison and paired t test for intragroup comparisons. RESULTS: At the 12-month follow-up, both Beautifil II LS and Filtek Z250XT exhibited high clinical success rates, with 100% and 96% success rates, respectively. Beautifil II LS restorations had a 4% lower risk of failure compared to Filtek Z250XT (ARR = 4.0 (95% CI -12.6 to 19.5, P > 0.05)). The mean wear after 12 months was 0.036 ± 0.01 mm for Beautifil II LS and 0.038 ± 0.01 mm for Filtek Z250XT. The difference between groups was minimal (0.0026 mm; 95% CI: -0.0271 to 0.0324) and not statistically significant (P = 0.8178). CONCLUSION: Low-shrinkage giomer showed satisfactory clinical performance and wear resistance compared to nanohybrid resin composite after one year. Both materials are considered clinically acceptable as per the American Dental Association (ADA) standards.

Authors

Institutions

Publication Details

Journal
BDJ Open
Published
2026-04-13
DOI
https://doi.org/10.1038/s41405-026-00423-2
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical performance of low-shrinkage giomer compared to nanohybrid resin composite in proximal restorations after one year: a randomized clinical trial

Omar Shaalan, Marwa I. AbdelHafez, Heba Hamza
BDJ Open
Dental materials and restorations
article

Clinical performance of low-shrinkage giomer compared to nanohybrid resin composite in proximal restorations after one year: a randomized clinical trial

Omar Shaalan, Marwa I. AbdelHafez, Heba Hamza
article en

Abstract

OBJECTIVES: The present study assesses the clinical performance and occlusal wear of low-shrinkage giomer and nanohybrid composite in proximal restorations. METHODS: Fifty participants with proximal caries in posterior teeth (n = 25) were recruited. Teeth were restored with either conventional nano-hybrid composite (Filtek Z250XT, 3M ESPE, USA) or low-shrinkage giomer (Beautifil II LS, Shofu Inc, Japan). Clinical performance was assessed using revised FDI criteria at baseline, 6 and 12 months. Wear was assessed after 12 months by using 3D inspection and metrology software (Geomagic Control X; 3D Systems, USA). FDI scores were analyzed using Chi‑square test for intergroup comparisons and Cochran's Q‑test for intragroup comparisons. Wear data were analyzed using independent t test for intergroup comparison and paired t test for intragroup comparisons. RESULTS: At the 12-month follow-up, both Beautifil II LS and Filtek Z250XT exhibited high clinical success rates, with 100% and 96% success rates, respectively. Beautifil II LS restorations had a 4% lower risk of failure compared to Filtek Z250XT (ARR = 4.0 (95% CI -12.6 to 19.5, P > 0.05)). The mean wear after 12 months was 0.036 ± 0.01 mm for Beautifil II LS and 0.038 ± 0.01 mm for Filtek Z250XT. The difference between groups was minimal (0.0026 mm; 95% CI: -0.0271 to 0.0324) and not statistically significant (P = 0.8178). CONCLUSION: Low-shrinkage giomer showed satisfactory clinical performance and wear resistance compared to nanohybrid resin composite after one year. Both materials are considered clinically acceptable as per the American Dental Association (ADA) standards.

BDJ OpenVol. 12(1)
Ain Shams University (EG), Cairo University (EG), Egypt Nanotechnology Center (EG), Egyptian Russian University (EG)
Science and Technology Development Fund
Openalex Percentile: Top 25%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.