Volumetric Assessment of Blow-Out Fractures With Automated Segmentation Benefits Thinner Computed Tomography Slice Thickness: A Retrospective Case-Control Study

The volume of the orbital vault is an important factor in assessing asymmetry, blow-out fractures, and postoperative outcomes after reconstruction. However, manual segmentation is time-consuming and may depend on the radiologist's experience. The automated segmentation tool speeds up the process, but it may not yield results as similar to manual segmentation. The orbital volume of 34 patients suffering from orbital blow-out fracture requiring surgical intervention and pre- and postoperative computed tomography (CT) data were assessed with an automated segmentation tool (case) and manual segmentation (control). Pre- and postoperative CTs of fractured and intact orbits were assessed (n=136). Slice thickness as a factor affecting the repeatability results of automated segmentation was analysed with the Mann-Whitney U test. Agreement between methods and measurements was assessed using the interclass correlation coefficients (ICC), and the repeatability of each method was tested using intraclass correlation coefficients (ICC). Compared with thicker (2 mm+) slices, 1 mm or less slice thickness showed significantly better repeatability between pre- and postoperative imaging when automated segmentation was used (P=0.028), although overall repeatability was very good in both methods; ICC was 0.83 in manual segmentation and 0.92 in automated segmentation. Correlation between automated and manual segmentation was rather poor in both intact and fractured orbits in pre- and postoperative imaging (ICC: 0.57 and 0.50 in intact orbits; 0.41 and 0.67 in fractured and reconstructed orbits). Automated segmentation is a reliable and repeatable method in volumetric assessment, especially with a slice thickness of 1 mm or less. However, volumetric results do not correlate with manual segmentation.

Authors

Institutions

Publication Details

Journal
Journal of Craniofacial Surgery
Published
2026-04-13
DOI
https://doi.org/10.1097/scs.0000000000012681
Primary Topic
Facial Trauma and Fracture Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Volumetric Assessment of Blow-Out Fractures With Automated Segmentation Benefits Thinner Computed Tomography Slice Thickness: A Retrospective Case-Control Study

Juho Suojanen, Niilo Lusila, Eeva Kormi, Ville Männistö et al.
Journal of Craniofacial Surgery
Facial Trauma and Fracture Management
article

Volumetric Assessment of Blow-Out Fractures With Automated Segmentation Benefits Thinner Computed Tomography Slice Thickness: A Retrospective Case-Control Study

Juho Suojanen, Niilo Lusila, Eeva Kormi, Ville Männistö, Pilvi Mäntynen
article en

Abstract

The volume of the orbital vault is an important factor in assessing asymmetry, blow-out fractures, and postoperative outcomes after reconstruction. However, manual segmentation is time-consuming and may depend on the radiologist's experience. The automated segmentation tool speeds up the process, but it may not yield results as similar to manual segmentation. The orbital volume of 34 patients suffering from orbital blow-out fracture requiring surgical intervention and pre- and postoperative computed tomography (CT) data were assessed with an automated segmentation tool (case) and manual segmentation (control). Pre- and postoperative CTs of fractured and intact orbits were assessed (n=136). Slice thickness as a factor affecting the repeatability results of automated segmentation was analysed with the Mann-Whitney U test. Agreement between methods and measurements was assessed using the interclass correlation coefficients (ICC), and the repeatability of each method was tested using intraclass correlation coefficients (ICC). Compared with thicker (2 mm+) slices, 1 mm or less slice thickness showed significantly better repeatability between pre- and postoperative imaging when automated segmentation was used (P=0.028), although overall repeatability was very good in both methods; ICC was 0.83 in manual segmentation and 0.92 in automated segmentation. Correlation between automated and manual segmentation was rather poor in both intact and fractured orbits in pre- and postoperative imaging (ICC: 0.57 and 0.50 in intact orbits; 0.41 and 0.67 in fractured and reconstructed orbits). Automated segmentation is a reliable and repeatable method in volumetric assessment, especially with a slice thickness of 1 mm or less. However, volumetric results do not correlate with manual segmentation.

Journal of Craniofacial Surgery
University of Helsinki (FI), Päijät-Hämeen Keskussairaala (FI)
No poverty
Openalex Percentile: Top 15%
Facial Trauma and Fracture Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.