Rate-Dependent Mechanical Behavior of Human Femoropopliteal Arteries in Biaxial Testing

Introduction: Arteries, like other soft tissues, exhibit viscoelastic mechanical behavior, meaning their response to stress and strain is time dependent. This implies that the way arteries deform depends not only on the amount of force applied but also on the rate at which the force is applied. This study investigates the effects of different loading rates on the mechanical behavior of human femoropopliteal arteries (FPAs) to understand their rate-dependent characteristics. Methods: Human FPA specimens were collected from 14 donors, including 7 males and 7 females, aged 45-55 years. A 10x10 mm segment was isolated, mounted onto a biaxial testing device, and subjected to varying loading rates (10 to 50 mN/s). Mechanical responses were recorded, and stress-stretch curves were analyzed. Statistical analyses, including mixed-design ANOVA, assessed the impact of sex and loading rates on tissue stiffness. Results: Results indicated significant loading-rate dependency, particularly in the circumferential direction. Stretch values decreased with increasing loading rates, more prominently in the circumferential than in the longitudinal direction (p-value<0.01). Statistical analyses revealed no significant interaction between sex and loading rate, though male arteries exhibited slightly higher compliance than female arteries. Discussion: The findings demonstrate that the mechanical response of FPAs is highly dependent on the loading rate, with more pronounced effects observed in the circumferential direction. At higher loading rates, the human FPAs demonstrated a stiffer response in the circumferential direction. Dedication: We dedicate this work to the memory of our late student, Ali Zolfaghari Sichani, who passed away tragically during his doctoral studies. Ali performed the majority of the experiments and the initial analysis reported in this paper. His passion, dedication, and hard work were the foundation of this research, and he is deeply missed.

Authors

Institutions

Publication Details

Journal
bioRxiv (Cold Spring Harbor Laboratory)
Published
2026-04-13
DOI
https://doi.org/10.64898/2026.04.09.717509
Primary Topic
Elasticity and Material Modeling
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rate-Dependent Mechanical Behavior of Human Femoropopliteal Arteries in Biaxial Testing

Sayed Ahmadreza Razian, Bahman Kargarbahrkhazar, Majid Jadidi
bioRxiv (Cold Spring Harbor Laboratory)
Elasticity and Material Modeling
article

Rate-Dependent Mechanical Behavior of Human Femoropopliteal Arteries in Biaxial Testing

Sayed Ahmadreza Razian, Bahman Kargarbahrkhazar, Majid Jadidi
article en

Abstract

Introduction: Arteries, like other soft tissues, exhibit viscoelastic mechanical behavior, meaning their response to stress and strain is time dependent. This implies that the way arteries deform depends not only on the amount of force applied but also on the rate at which the force is applied. This study investigates the effects of different loading rates on the mechanical behavior of human femoropopliteal arteries (FPAs) to understand their rate-dependent characteristics. Methods: Human FPA specimens were collected from 14 donors, including 7 males and 7 females, aged 45-55 years. A 10x10 mm segment was isolated, mounted onto a biaxial testing device, and subjected to varying loading rates (10 to 50 mN/s). Mechanical responses were recorded, and stress-stretch curves were analyzed. Statistical analyses, including mixed-design ANOVA, assessed the impact of sex and loading rates on tissue stiffness. Results: Results indicated significant loading-rate dependency, particularly in the circumferential direction. Stretch values decreased with increasing loading rates, more prominently in the circumferential than in the longitudinal direction (p-value<0.01). Statistical analyses revealed no significant interaction between sex and loading rate, though male arteries exhibited slightly higher compliance than female arteries. Discussion: The findings demonstrate that the mechanical response of FPAs is highly dependent on the loading rate, with more pronounced effects observed in the circumferential direction. At higher loading rates, the human FPAs demonstrated a stiffer response in the circumferential direction. Dedication: We dedicate this work to the memory of our late student, Ali Zolfaghari Sichani, who passed away tragically during his doctoral studies. Ali performed the majority of the experiments and the initial analysis reported in this paper. His passion, dedication, and hard work were the foundation of this research, and he is deeply missed.

bioRxiv (Cold Spring Harbor Laboratory)
University of Nebraska at Omaha (US)
Nebraska Tobacco Settlement Biomedical Research Development Fund, National Institute of General Medical Sciences
Good health and well-being, Gender equality
Openalex Percentile: Top 21%
Elasticity and Material Modeling
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.