Evaluation of Helical Pipe Geometry on Hydraulic Flocculation Efficiency for Turbid Water Treatment

The geometric configuration of helical tubes was assessed in relation to the hydraulic flocculation efficiency in the treatment of highly turbid water. The effect of evaluating different tube geometries (diameters of 0.019–0.025m), loop diameters (0.45–1 m) and flow rates (7.5–25·10−6 m3/s) on head loss, camp number (Gt), and residence time was evaluated. The highest turbidity removal efficiency of 85.56% was achieved with the optimized configuration of a 0.019 m tube diameter with a 0.45 m loop. The performance was less if flow rates were higher, the tubes or loops were larger and the flow rates were higher due to inadequate turbulence and less time for particle interaction. Results validate that compact helical configurations aid in low turbulence condition improvement of mixing and particle collision. The helical flow devices were proven to be easy and low cost alternatives to these systems. Future work should focus on scaling and the optimizing the coagulant. The study illustrated that helical flow devices are easy and inexpensive alternatives to decentralized systems. Future work should focus on scaling and coagulant optimization.

Authors

Publication Details

Journal
Environmental Research Engineering and Management
Published
2026-04-13
DOI
https://doi.org/10.5755/j01.erem.82.1.43549
Primary Topic
Coagulation and Flocculation Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Helical Pipe Geometry on Hydraulic Flocculation Efficiency for Turbid Water Treatment

Dina A. Yaseen, Saad Abu-Alhail Arab, Zainab Radhi Thamer
Environmental Research Engineering and Management
Coagulation and Flocculation Studies
article

Evaluation of Helical Pipe Geometry on Hydraulic Flocculation Efficiency for Turbid Water Treatment

Dina A. Yaseen, Saad Abu-Alhail Arab, Zainab Radhi Thamer
article en

Abstract

The geometric configuration of helical tubes was assessed in relation to the hydraulic flocculation efficiency in the treatment of highly turbid water. The effect of evaluating different tube geometries (diameters of 0.019–0.025m), loop diameters (0.45–1 m) and flow rates (7.5–25·10−6 m3/s) on head loss, camp number (Gt), and residence time was evaluated. The highest turbidity removal efficiency of 85.56% was achieved with the optimized configuration of a 0.019 m tube diameter with a 0.45 m loop. The performance was less if flow rates were higher, the tubes or loops were larger and the flow rates were higher due to inadequate turbulence and less time for particle interaction. Results validate that compact helical configurations aid in low turbulence condition improvement of mixing and particle collision. The helical flow devices were proven to be easy and low cost alternatives to these systems. Future work should focus on scaling and the optimizing the coagulant. The study illustrated that helical flow devices are easy and inexpensive alternatives to decentralized systems. Future work should focus on scaling and coagulant optimization.

Environmental Research Engineering and ManagementVol. 82(1)
Clean water and sanitation
Openalex Percentile: Top 20%
Coagulation and Flocculation Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.