Rethinking non-structural vulnerability of EC8-compliant steel buildings with glass façades

Non-structural components account for a significant share of building construction costs and strongly influence seismic performance and post-earthquake losses. Eurocode 8 Part 1 (EC8–1) recognises their importance, particularly in buildings with steel moment-resisting frames (SMRFs), yet provides limited guidance for the seismic assessment of acceleration-sensitive components (ASCs), such as point-fixed glass façade systems (PFGFSs). This study investigates the seismic vulnerability of structural components and non-structural components, including drift-sensitive components (DSCs) and ASCs, in mid-rise European SMRF buildings designed in accordance with EC8–1. Three index buildings with different inter-storey drift ratio (IDR) limits were analysed using 2250 nonlinear time-history simulations to derive fragility and vulnerability functions. A dedicated graphical user interface (GUI) toolkit was developed to support the systematic evaluation of structural and non-structural vulnerability. The results demonstrate a clear drift–acceleration trade-off: adopting the minimum IDR required for serviceability significantly reduces vulnerability of the structural system and DSCs, but leads to a marked increase in peak floor accelerations and vulnerability of ASCs. A detailed case study on PFGFSs, based on a validated three-dimensional numerical model and 15 pairs of recorded ground motions, shows that façade systems experience substantially higher IDR and peak floor acceleration than the main structure, with demands at roof level up to approximately 80% higher. The proposed fragility and vulnerability functions provide practical tools for seismic risk assessment and highlight the need to revise existing fragility thresholds and design provisions for acceleration-sensitive non-structural components in future European seismic codes.

Authors

Publication Details

Journal
Structures
Published
2026-04-13
DOI
https://doi.org/10.1016/j.istruc.2026.111832
Primary Topic
Structural Analysis of Composite Materials
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rethinking non-structural vulnerability of EC8-compliant steel buildings with glass façades

Chiara Bedon, Sandra Jordão, Rohola Rahnavard, Seyed Amin Hosseini et al.
Structures
Structural Analysis of Composite Materials
article

Rethinking non-structural vulnerability of EC8-compliant steel buildings with glass façades

Chiara Bedon, Sandra Jordão, Rohola Rahnavard, Seyed Amin Hosseini, Carlos Rebelo
article en

Abstract

Non-structural components account for a significant share of building construction costs and strongly influence seismic performance and post-earthquake losses. Eurocode 8 Part 1 (EC8–1) recognises their importance, particularly in buildings with steel moment-resisting frames (SMRFs), yet provides limited guidance for the seismic assessment of acceleration-sensitive components (ASCs), such as point-fixed glass façade systems (PFGFSs). This study investigates the seismic vulnerability of structural components and non-structural components, including drift-sensitive components (DSCs) and ASCs, in mid-rise European SMRF buildings designed in accordance with EC8–1. Three index buildings with different inter-storey drift ratio (IDR) limits were analysed using 2250 nonlinear time-history simulations to derive fragility and vulnerability functions. A dedicated graphical user interface (GUI) toolkit was developed to support the systematic evaluation of structural and non-structural vulnerability. The results demonstrate a clear drift–acceleration trade-off: adopting the minimum IDR required for serviceability significantly reduces vulnerability of the structural system and DSCs, but leads to a marked increase in peak floor accelerations and vulnerability of ASCs. A detailed case study on PFGFSs, based on a validated three-dimensional numerical model and 15 pairs of recorded ground motions, shows that façade systems experience substantially higher IDR and peak floor acceleration than the main structure, with demands at roof level up to approximately 80% higher. The proposed fragility and vulnerability functions provide practical tools for seismic risk assessment and highlight the need to revise existing fragility thresholds and design provisions for acceleration-sensitive non-structural components in future European seismic codes.

StructuresVol. 88
Fundação para a Ciência e a Tecnologia
Sustainable cities and communities
Openalex Percentile: Top 21%
Structural Analysis of Composite Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.