Effect of different bolus application methods on target dose in radiotherapy after radical mastectomy

Objective: To assess the impact of bolus addition methods on the target dose of radiotherapy following radical mastectomy for breast cancer. Methods: Thirty patients who underwent radiotherapy after radical mastectomy between January and August 2023 were included in this study. Each patient underwent two CT scans: CT1 (no bolus) and CT2 (with bolus placed on the chest wall). Using the CT1 images, a virtual bolus was added to create a radiotherapy Plan1 that met clinical and dosimetric requirements. Plan2 was generated from the CT2 images with the added bolus, and Plan3 was derived by copying Plan1 to CT2 to simulate the dose distribution during treatment. Radiotherapy plans were developed using volumetric-modulated arc therapy (VMAT) and intensity-modulated radiotherapy (IMRT) techniques. The dosimetric parameters for the target volume and organs at risk (OAR) were analyzed for each plan. Results: across all three plans (P < 0.05). Conclusion: The addition of a bolus during radiotherapy planning provides a more accurate reflection of the dose distribution in the target area and the dose received by OARs. The VMAT plan achieved better target conformity and significantly reduced monitor units, potentially shortening treatment time and improving machine efficiency.

Authors

Institutions

Publication Details

Journal
Frontiers in Oncology
Published
2026-04-13
DOI
https://doi.org/10.3389/fonc.2026.1806104
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of different bolus application methods on target dose in radiotherapy after radical mastectomy

Xinyu Zhao, Xiaojuan Sun, Hao Su, Feng Wang
Frontiers in Oncology
Advanced Radiotherapy Techniques
article

Effect of different bolus application methods on target dose in radiotherapy after radical mastectomy

Xinyu Zhao, Xiaojuan Sun, Hao Su, Feng Wang
article en

Abstract

Objective: To assess the impact of bolus addition methods on the target dose of radiotherapy following radical mastectomy for breast cancer. Methods: Thirty patients who underwent radiotherapy after radical mastectomy between January and August 2023 were included in this study. Each patient underwent two CT scans: CT1 (no bolus) and CT2 (with bolus placed on the chest wall). Using the CT1 images, a virtual bolus was added to create a radiotherapy Plan1 that met clinical and dosimetric requirements. Plan2 was generated from the CT2 images with the added bolus, and Plan3 was derived by copying Plan1 to CT2 to simulate the dose distribution during treatment. Radiotherapy plans were developed using volumetric-modulated arc therapy (VMAT) and intensity-modulated radiotherapy (IMRT) techniques. The dosimetric parameters for the target volume and organs at risk (OAR) were analyzed for each plan. Results: across all three plans (P < 0.05). Conclusion: The addition of a bolus during radiotherapy planning provides a more accurate reflection of the dose distribution in the target area and the dose received by OARs. The VMAT plan achieved better target conformity and significantly reduced monitor units, potentially shortening treatment time and improving machine efficiency.

Frontiers in OncologyVol. 16
Shandong University of Aeronautics (CN)
Good health and well-being
Openalex Percentile: Top 23%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.