Determination of 14 Rare Earth Elements in Seawater by Solid Phase Extraction-Inductively Coupled Plasma Mass Spectrometry

A solid-phase extraction (SPE) method utilizing an iminodiacetic acid-based chelating resin as the stationary phase was developed for the determination of 14 rare earth elements in seawater by inductively coupled plasma mass spectrometry (ICP-MS). Adjust the pH value of water sample to the range of 8.5~9.0, followed by adsorption and enrichment of the target elements through solid-phase extraction. The detection limit of rare earth elements was 0.017 μg/L~0.024 μg/L,the relative standard deviation (RSD) of the method was 2.7%~4.8%,the recovery rates of spiking was 81.4%~105.0%. The proposed methodology is characterized by operational simplicity, high sensitivity, and efficiency, yielding highly satisfactory experimental results.

Authors

Publication Details

Journal
Chinese Rare Earths
Published
2026-04-01
DOI
https://doi.org/10.3724/s1004-0277.202602016
Primary Topic
Geochemistry and Elemental Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of 14 Rare Earth Elements in Seawater by Solid Phase Extraction-Inductively Coupled Plasma Mass Spectrometry

Ling-Yun Dong, Pei-dong FAN, Liang-liang JIA
Chinese Rare Earths
Geochemistry and Elemental Analysis
article

Determination of 14 Rare Earth Elements in Seawater by Solid Phase Extraction-Inductively Coupled Plasma Mass Spectrometry

Ling-Yun Dong, Pei-dong FAN, Liang-liang JIA
article en

Abstract

A solid-phase extraction (SPE) method utilizing an iminodiacetic acid-based chelating resin as the stationary phase was developed for the determination of 14 rare earth elements in seawater by inductively coupled plasma mass spectrometry (ICP-MS). Adjust the pH value of water sample to the range of 8.5~9.0, followed by adsorption and enrichment of the target elements through solid-phase extraction. The detection limit of rare earth elements was 0.017 μg/L~0.024 μg/L,the relative standard deviation (RSD) of the method was 2.7%~4.8%,the recovery rates of spiking was 81.4%~105.0%. The proposed methodology is characterized by operational simplicity, high sensitivity, and efficiency, yielding highly satisfactory experimental results.

Chinese Rare EarthsVol. 47(2)
Life below water
Openalex Percentile: Top 7%
Geochemistry and Elemental Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.