Improving patient treatment accuracy using transit dosimetry with Electronic Portal Imaging Device images and deep learning

Background and Purpose: Electronic portal imaging devices (EPID) can be utilized for transit in vivo dosimetry (IVD). A major limitation of standard amorphous Silicon EPID detectors for usage IVD is their non-linear detector response to water equivalent dose. Labor-intensive calibration and correction procedures are needed, limiting their practicality for routine clinical use. The purpose of this work was to develop a deep learning (DL) framework, based on data acquisitions and treatment planning system (TPS) dose simulations, which reconstructed water equivalent dose from transit EPID images. Materials and methods: -index analysis with a 3%/3 mm and 5%/5 mm criterion. Results: for the 3%/3 mm and 5%/5 mm criteria, respectively. Median passing rates were 98.3% for the 3%/3 mm and 100% for the 5%/5 mm criterion, respectively, demonstrating high accuracy in reconstructing portal dose from EPID. The predictions were completed within 1 s. Conclusions: Our DL framework enabled fast and accurate reconstruction of portal dose from transit EPID images. Once trained on clinical data, it may reduce complex corrections, supporting safe and effective treatments that meet modern regulatory standards.

Authors

Institutions

Publication Details

Journal
Physics and Imaging in Radiation Oncology
Published
2026-04-13
DOI
https://doi.org/10.1016/j.phro.2026.100966
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improving patient treatment accuracy using transit dosimetry with Electronic Portal Imaging Device images and deep learning

G. Pirrone, Michele Avanzo, Emmanuel Uwitonze, Francesca Lizzi et al.
Physics and Imaging in Radiation Oncology
Advanced Radiotherapy Techniques
article

Improving patient treatment accuracy using transit dosimetry with Electronic Portal Imaging Device images and deep learning

G. Pirrone, Michele Avanzo, Emmanuel Uwitonze, Francesca Lizzi, Alessandra Retico, Lorenzo Marini, A. Kraan, Cinzia Talamonti, Icro Meattini, Carlotta Mozzi
article en

Abstract

Background and Purpose: Electronic portal imaging devices (EPID) can be utilized for transit in vivo dosimetry (IVD). A major limitation of standard amorphous Silicon EPID detectors for usage IVD is their non-linear detector response to water equivalent dose. Labor-intensive calibration and correction procedures are needed, limiting their practicality for routine clinical use. The purpose of this work was to develop a deep learning (DL) framework, based on data acquisitions and treatment planning system (TPS) dose simulations, which reconstructed water equivalent dose from transit EPID images. Materials and methods: -index analysis with a 3%/3 mm and 5%/5 mm criterion. Results: for the 3%/3 mm and 5%/5 mm criteria, respectively. Median passing rates were 98.3% for the 3%/3 mm and 100% for the 5%/5 mm criterion, respectively, demonstrating high accuracy in reconstructing portal dose from EPID. The predictions were completed within 1 s. Conclusions: Our DL framework enabled fast and accurate reconstruction of portal dose from transit EPID images. Once trained on clinical data, it may reduce complex corrections, supporting safe and effective treatments that meet modern regulatory standards.

Physics and Imaging in Radiation OncologyVol. 39
University of Pisa (IT), Istituto Nazionale di Fisica Nucleare (IT), Maastricht University Medical Centre (NL), Azienda Ospedaliero-Universitaria Careggi (IT), Centro di Riferimento Oncologico (IT), Rwanda Biomedical Center (RW), Istituti di Ricovero e Cura a Carattere Scientifico (IT), Istituto Nazionale di Fisica Nucleare, Sezione di Pisa (IT), Maastro Clinic (NL), University of Florence (IT)
Instituto Nazionale di Fisica Nucleare
Openalex Percentile: Top 19%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.