Research on mK-level thermal control design and environmental test verification for a space-borne gravitational-wave telescope

• Design and fabricate an off-axis four-mirror gravitational-wave telescope • Large aperture telescope with a primary mirror up to 300mm • Use real-size telescope thermal prototype as the experimental subject • Establish a test system capable of simulating the complex space environment • Design and implement a multi-stage active–passive thermal-control system • Limiting temperature fluctuations of the telescope key locations to mK level Gravitational wave telescopes impose extremely stringent requirements on thermal stability. The key optical elements are required to maintain temperature control accuracy at the millikelvin (mK) level to suppress the impact of thermal noise on optical measurements. In this work, an off-axis four-mirror gravitational wave detection telescope was tested which had the primary mirror aperture up to 300mm. A multi-stage thermal suppression system was developed for the gravitational wave detection telescope by integrating multiple active and passive thermal control techniques. A high-precision temperature measurement and control scheme was established, and the system’s performance was experimentally evaluated under cryogenic vacuum conditions in a space environment simulation facility. The results demonstrate that the proposed multi-stage thermal suppression system could maintain the temperature fluctuation of key elements in the telescope within ±3.0mK over a continuous 2.2h period. In the center point of the primary mirror back surface, it achieved a temperature stability of ±1.6mK. These results proved the effectiveness of the high-stability multistage heat suppression techniques and high-precision temperature measurement/control method, providing a potential choice for the thermal design of future space-based gravitational wave detectors.

Authors

Institutions

Publication Details

Journal
Results in Engineering
Published
2026-04-12
DOI
https://doi.org/10.1016/j.rineng.2026.110522
Primary Topic
Pulsars and Gravitational Waves Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on mK-level thermal control design and environmental test verification for a space-borne gravitational-wave telescope

Qinfang Chen, Lei Qin, Chenjie Wang, You Mu et al.
Results in Engineering
Pulsars and Gravitational Waves Research
article

Research on mK-level thermal control design and environmental test verification for a space-borne gravitational-wave telescope

Qinfang Chen, Lei Qin, Chenjie Wang, You Mu, Desheng Wen, Lei Hang Yang Xi, Yixin Ma, Tian Wang, Chenhui Xia, Xuyang Li, Sen Yang, Jing Ye, Dejin Qin, Tao Li, Guangwen Jiang
article en

Abstract

• Design and fabricate an off-axis four-mirror gravitational-wave telescope • Large aperture telescope with a primary mirror up to 300mm • Use real-size telescope thermal prototype as the experimental subject • Establish a test system capable of simulating the complex space environment • Design and implement a multi-stage active–passive thermal-control system • Limiting temperature fluctuations of the telescope key locations to mK level Gravitational wave telescopes impose extremely stringent requirements on thermal stability. The key optical elements are required to maintain temperature control accuracy at the millikelvin (mK) level to suppress the impact of thermal noise on optical measurements. In this work, an off-axis four-mirror gravitational wave detection telescope was tested which had the primary mirror aperture up to 300mm. A multi-stage thermal suppression system was developed for the gravitational wave detection telescope by integrating multiple active and passive thermal control techniques. A high-precision temperature measurement and control scheme was established, and the system’s performance was experimentally evaluated under cryogenic vacuum conditions in a space environment simulation facility. The results demonstrate that the proposed multi-stage thermal suppression system could maintain the temperature fluctuation of key elements in the telescope within ±3.0mK over a continuous 2.2h period. In the center point of the primary mirror back surface, it achieved a temperature stability of ±1.6mK. These results proved the effectiveness of the high-stability multistage heat suppression techniques and high-precision temperature measurement/control method, providing a potential choice for the thermal design of future space-based gravitational wave detectors.

Results in EngineeringVol. 30
Xi'an Institute of Optics and Precision Mechanics (CN), Xi'an Jiaotong University (CN)
China Postdoctoral Science Foundation, National Key Research and Development Program of China, Natural Science Basic Research Program of Shaanxi Province
Openalex Percentile: Top 17%
Pulsars and Gravitational Waves Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.