Time-of-flight scanning transmission ion microscopy with high energy resolution in the low keV range

A prototype scanning transmission ion microscope (STIM) with time-of-flight (ToF) capabilities has been developed at the Luxembourg Institute of Science and Technology. It simultaneously collects 2D sample plane, 2D detector plane, and time-of-flight data to generate rich 5D datasets, with a sample spatial resolution of around 2 μm, a detector angular resolution of 0.01°, and a ToF resolution of under 1 ns. Pulsed beam chopping was implemented to achieve the sub-ns time resolution. At 25 keV, an energy resolution of ∼100 eV in ion energy loss spectroscopy is achieved for the flight path of 470 mm. The system is demonstrated for an application of sample thickness measurements for partially eroded metallic thin films of Pd, Pt, and Au that are nominally 2-3 nm thick. The experimental results are compared to theoretical results from SRIM for the ion energy-loss per unit thickness, which indicate that the energy resolution of 100 eV gives a theoretical thickness sensitivity of ∼0.5 nm for a thin Pd film.

Authors

Institutions

Publication Details

Journal
Micron
Published
2026-04-12
DOI
https://doi.org/10.1016/j.micron.2026.104038
Primary Topic
Ion-surface interactions and analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Time-of-flight scanning transmission ion microscopy with high energy resolution in the low keV range

Dustin Andersen, Santhana Eswara, Tom Wirtz, Rathaiah Pureti
Micron
Ion-surface interactions and analysis
article

Time-of-flight scanning transmission ion microscopy with high energy resolution in the low keV range

Dustin Andersen, Santhana Eswara, Tom Wirtz, Rathaiah Pureti
article en

Abstract

A prototype scanning transmission ion microscope (STIM) with time-of-flight (ToF) capabilities has been developed at the Luxembourg Institute of Science and Technology. It simultaneously collects 2D sample plane, 2D detector plane, and time-of-flight data to generate rich 5D datasets, with a sample spatial resolution of around 2 μm, a detector angular resolution of 0.01°, and a ToF resolution of under 1 ns. Pulsed beam chopping was implemented to achieve the sub-ns time resolution. At 25 keV, an energy resolution of ∼100 eV in ion energy loss spectroscopy is achieved for the flight path of 470 mm. The system is demonstrated for an application of sample thickness measurements for partially eroded metallic thin films of Pd, Pt, and Au that are nominally 2-3 nm thick. The experimental results are compared to theoretical results from SRIM for the ion energy-loss per unit thickness, which indicate that the energy resolution of 100 eV gives a theoretical thickness sensitivity of ∼0.5 nm for a thin Pd film.

MicronVol. 205
Luxembourg Institute of Science and Technology (LU)
Fonds National de la Recherche Luxembourg
Affordable and clean energy
Openalex Percentile: Top 21%
Ion-surface interactions and analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.