Full percutaneous decannulation of VA-ECMO using MANTA® and Femoseal® devices: a propensity-score based study

Percutaneous veno-arterial extracorporeal membrane oxygenation (VA-ECMO) implantation reduces infectious complications compared with surgical cannulation. However, arterial decannulation using manual compression remains associated with bleeding, vascular injury, and infection. We evaluated a fully percutaneous decannulation strategy (FP-D) combining MANTA® and Femoseal® devices. All patients undergoing FP-D between October 2020 and May 2022 in our institution were included. Outcomes were compared with a historical cohort decannulated using manual compression (MC). The primary endpoint was surgical revision after decannulation. Secondary endpoints included major bleeding, transfusion, vascular complications, infection, and 30-day survival. A propensity score weighting approach was performed to adjust for baseline differences. Among 497 patients treated with percutaneous VA-ECMO, 250 underwent FP-D and 247 MC. After propensity score, FP-D significantly reduced surgical revision (3.9% vs. 7.2%; RR 0.55, 95% CI 0.32–0.94; p = 0.0311), infection requiring surgery (3.7% vs. 8.4%; RR 0.44, 95% CI 0.25–0.77; p = 0.004), and major bleeding (1.4% vs. 11%; RR 0.13, 95% CI 0.06–0.30; p < 0.0001), with lower transfusion requirements (7.1% vs. 45.7%; RR 0.16, 95% CI 0.11–0.22; p < 0.0001). Thirty-day death was comparable between groups (8,2% vs. 5,57%; p = 0.1316). Systematic CT scans revealed frequent but mostly silent arterial lesions after FP-D. FP-D markedly reduced bleeding, transfusion, infection, and surgical revision compared with manual compression, while preserving short-term survival. Systematic imaging identified frequent subclinical vascular lesions, supporting targeted surveillance and endovascular management when appropriate.

Authors

Institutions

Publication Details

Journal
Critical Care
Published
2026-04-12
DOI
https://doi.org/10.1186/s13054-026-06012-x
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Full percutaneous decannulation of VA-ECMO using MANTA® and Femoseal® devices: a propensity-score based study

Nathalie Nardone, Pichoy Danial, Aude Carillion, Elodie Berg et al.
Critical Care
Mechanical Circulatory Support Devices
article

Full percutaneous decannulation of VA-ECMO using MANTA® and Femoseal® devices: a propensity-score based study

Nathalie Nardone, Pichoy Danial, Aude Carillion, Elodie Berg, Charifa Nazoiri, Cosimo D’Alessandro, Charles Juvin, Pascal Leprince, Adrien Bougle, Alain Combes, Guillaume Lebreton, Marc Pineton De Chambrun
article en

Abstract

Percutaneous veno-arterial extracorporeal membrane oxygenation (VA-ECMO) implantation reduces infectious complications compared with surgical cannulation. However, arterial decannulation using manual compression remains associated with bleeding, vascular injury, and infection. We evaluated a fully percutaneous decannulation strategy (FP-D) combining MANTA® and Femoseal® devices. All patients undergoing FP-D between October 2020 and May 2022 in our institution were included. Outcomes were compared with a historical cohort decannulated using manual compression (MC). The primary endpoint was surgical revision after decannulation. Secondary endpoints included major bleeding, transfusion, vascular complications, infection, and 30-day survival. A propensity score weighting approach was performed to adjust for baseline differences. Among 497 patients treated with percutaneous VA-ECMO, 250 underwent FP-D and 247 MC. After propensity score, FP-D significantly reduced surgical revision (3.9% vs. 7.2%; RR 0.55, 95% CI 0.32–0.94; p = 0.0311), infection requiring surgery (3.7% vs. 8.4%; RR 0.44, 95% CI 0.25–0.77; p = 0.004), and major bleeding (1.4% vs. 11%; RR 0.13, 95% CI 0.06–0.30; p < 0.0001), with lower transfusion requirements (7.1% vs. 45.7%; RR 0.16, 95% CI 0.11–0.22; p < 0.0001). Thirty-day death was comparable between groups (8,2% vs. 5,57%; p = 0.1316). Systematic CT scans revealed frequent but mostly silent arterial lesions after FP-D. FP-D markedly reduced bleeding, transfusion, infection, and surgical revision compared with manual compression, while preserving short-term survival. Systematic imaging identified frequent subclinical vascular lesions, supporting targeted surveillance and endovascular management when appropriate.

Critical Care
Inserm (FR), Délégation Paris 7 (FR), Sorbonne Université (FR), Pitié-Salpêtrière Hospital (FR), Université Paris 1 Panthéon-Sorbonne (FR), Université de Rouen Normandie (FR)
Good health and well-being
Openalex Percentile: Top 26%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.