Novelty prefabricated concrete beam‐to‐column joint using steel hybrid connection: Concept, test, and numerical investigation

Abstract The reliable connection between precast beams and columns is critical for prefabricated concrete (PC) frames to resist earthquakes. To improve the seismic performance of PC frames, an innovative joint with steel hybrid connections has been proposed, considering the superior structural performance and reliability of connections adopted in steel structure. In the paper, three beam‐to‐column joint specimens, including two proposed joints and one monolithic joint, were tested under lateral cyclic load. Results showed the proposed hybrid connection joint achieves the goal of strong joint‐weak member and strong column‐weak beam. For the proposed joint, premature failure was observed at the hybrid‐connected area of PC beams due to the pull‐out of longitudinal rebars and the core region of the joint was basically intact. In comparison, the damage in the core zone of the monolithic joint, caused by shear action, was more significant. The load‐carrying capabilities of the proposed joint and monolithic one were comparable. During the stage with small deformation, lateral stiffness and energy dissipation of the hybrid connection joint were less than the monolithic specimen. When the deformation was large, however, those of the proposed joint became higher before the pull‐out of longitudinal rebars, which may demonstrate the potential for excellent seismic performance. Moreover, a finite element model, considering the contacts of hybrid connections in detail, was established using ABAQUS software and validated against experimental results. According to numerical research, the anticipated failure mode was achieved when the hybrid connections of the PC beam and column were reliable. In the future, the hybrid connection construction of the PC beam still requires enhancement.

Authors

Institutions

Publication Details

Journal
Structural Concrete
Published
2026-04-12
DOI
https://doi.org/10.1002/suco.70558
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novelty prefabricated concrete beam‐to‐column joint using steel hybrid connection: Concept, test, and numerical investigation

Zhihao Fang, Yongkang Ji, Gangfeng Yao, Yinyin Wu et al.
Structural Concrete
Structural Load-Bearing Analysis
article

Novelty prefabricated concrete beam‐to‐column joint using steel hybrid connection: Concept, test, and numerical investigation

Zhihao Fang, Yongkang Ji, Gangfeng Yao, Yinyin Wu, Youzhen Fang
article en

Abstract

Abstract The reliable connection between precast beams and columns is critical for prefabricated concrete (PC) frames to resist earthquakes. To improve the seismic performance of PC frames, an innovative joint with steel hybrid connections has been proposed, considering the superior structural performance and reliability of connections adopted in steel structure. In the paper, three beam‐to‐column joint specimens, including two proposed joints and one monolithic joint, were tested under lateral cyclic load. Results showed the proposed hybrid connection joint achieves the goal of strong joint‐weak member and strong column‐weak beam. For the proposed joint, premature failure was observed at the hybrid‐connected area of PC beams due to the pull‐out of longitudinal rebars and the core region of the joint was basically intact. In comparison, the damage in the core zone of the monolithic joint, caused by shear action, was more significant. The load‐carrying capabilities of the proposed joint and monolithic one were comparable. During the stage with small deformation, lateral stiffness and energy dissipation of the hybrid connection joint were less than the monolithic specimen. When the deformation was large, however, those of the proposed joint became higher before the pull‐out of longitudinal rebars, which may demonstrate the potential for excellent seismic performance. Moreover, a finite element model, considering the contacts of hybrid connections in detail, was established using ABAQUS software and validated against experimental results. According to numerical research, the anticipated failure mode was achieved when the hybrid connections of the PC beam and column were reliable. In the future, the hybrid connection construction of the PC beam still requires enhancement.

Structural Concrete
Suzhou University of Science and Technology (CN)
National Natural Science Foundation of China
Sustainable cities and communities
Openalex Percentile: Top 24%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.