Efficacy and Safety of Pre-Endoscopy Regimens for Mucosal Visualization During Sedated Esophagogastro-duodenoscopy: A Randomized Controlled Trial

Background: Optimal mucosal visibility during esophagogastroduodenoscopy (EGD) is critical for diagnostic accuracy but is often impaired by the presence of mucus and bubbles. This study aimed to compare the efficacy and safety of four premedication regimens for mucosal visualization during sedated EGD. Methods: A double-blind randomized controlled trial was conducted at the Endoscopy Unit of Dr. Zainoel Abidin General Hospital, Banda Aceh, Indonesia, from January to December 2024. Patients scheduled for elective diagnostic EGD were randomly assigned to: Group 1 (simethicone 40 mg at 30 minutes before the procedure), Group 2 (simethicone 40 mg + 100 mL 5% sodium bicarbonate at 2 hours), Group 3 (simethicone 40 mg + N-acetylcysteine 600 mg in 100 mL water at 2 hours), or Group 4 (all three agents at 2 hours). Primary outcomes were mucosal visibility (6-site, 3-point scoring system with lower scores indicating superior mucosal visibility); procedural metrics (irrigation volume and duration); and safety (the lowest recorded SpO₂%). Data were analyzed using ANOVA or Kruskal–Wallis for continuous variables, and Chi-square or Fisher’s exact test for categorical variables, with post hoc testing as applicable. Results: A total of 168 patients were randomized into four groups (n=42 each). Groups 3 and 4 showed superior mucosal visibility compared to Groups 1 and 2 (p=0.004), with no significant difference between Groups 3 and 4. Irrigation volume differed significantly (p=0.018), lowest in Group 4. Group 3 had the shortest procedure time (3.1 ± 1.2 minutes), significantly more efficient than Groups 1 and 2, but similar to Group 4. Oxygen saturation was slightly lower in Group 3 (p<0.005), though all groups remained within safe clinical limits. Conclusions: Simethicone and N-acetylcysteine given two hours before endoscopy effectively enhanced mucosal visibility and procedural efficiency without compromising safety, offering a practical alternative to more complex regimens.

Authors

Institutions

Publication Details

Journal
DOAJ (DOAJ: Directory of Open Access Journals)
Published
2026-04-01
Primary Topic
Colorectal Cancer Screening and Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Efficacy and Safety of Pre-Endoscopy Regimens for Mucosal Visualization During Sedated Esophagogastro-duodenoscopy: A Randomized Controlled Trial

Azzaki Abubakar, Desi Maghfirah, Fauzi Maulana Yusuf
DOAJ (DOAJ: Directory of Open Access Journals)
Colorectal Cancer Screening and Detection
article

Efficacy and Safety of Pre-Endoscopy Regimens for Mucosal Visualization During Sedated Esophagogastro-duodenoscopy: A Randomized Controlled Trial

Azzaki Abubakar, Desi Maghfirah, Fauzi Maulana Yusuf
article en

Abstract

Background: Optimal mucosal visibility during esophagogastroduodenoscopy (EGD) is critical for diagnostic accuracy but is often impaired by the presence of mucus and bubbles. This study aimed to compare the efficacy and safety of four premedication regimens for mucosal visualization during sedated EGD. Methods: A double-blind randomized controlled trial was conducted at the Endoscopy Unit of Dr. Zainoel Abidin General Hospital, Banda Aceh, Indonesia, from January to December 2024. Patients scheduled for elective diagnostic EGD were randomly assigned to: Group 1 (simethicone 40 mg at 30 minutes before the procedure), Group 2 (simethicone 40 mg + 100 mL 5% sodium bicarbonate at 2 hours), Group 3 (simethicone 40 mg + N-acetylcysteine 600 mg in 100 mL water at 2 hours), or Group 4 (all three agents at 2 hours). Primary outcomes were mucosal visibility (6-site, 3-point scoring system with lower scores indicating superior mucosal visibility); procedural metrics (irrigation volume and duration); and safety (the lowest recorded SpO₂%). Data were analyzed using ANOVA or Kruskal–Wallis for continuous variables, and Chi-square or Fisher’s exact test for categorical variables, with post hoc testing as applicable. Results: A total of 168 patients were randomized into four groups (n=42 each). Groups 3 and 4 showed superior mucosal visibility compared to Groups 1 and 2 (p=0.004), with no significant difference between Groups 3 and 4. Irrigation volume differed significantly (p=0.018), lowest in Group 4. Group 3 had the shortest procedure time (3.1 ± 1.2 minutes), significantly more efficient than Groups 1 and 2, but similar to Group 4. Oxygen saturation was slightly lower in Group 3 (p<0.005), though all groups remained within safe clinical limits. Conclusions: Simethicone and N-acetylcysteine given two hours before endoscopy effectively enhanced mucosal visibility and procedural efficiency without compromising safety, offering a practical alternative to more complex regimens.

DOAJ (DOAJ: Directory of Open Access Journals)
Universitas Syiah Kuala (ID)
Good health and well-being
Openalex Percentile: Top 28%
Colorectal Cancer Screening and Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.