Automated peak detection, isotyping and quantitation of M-proteins by MALDI-TOF MS for replacement of immunofixation and serum protein electrophoresis

In 2018, the Mayo Clinic Protein Immunology Laboratory switched from immunofixation electrophoresis to a MALDI-TOF MS (Mass-Fix) method for the isotyping of M-proteins with a goal of replacing serum protein electrophoresis (SPEP) later. This study defines the performance characteristics of the MALDI-TOF MS method (Q-Mass-Fix) for simultaneous quantitation and isotyping of M-proteins in conjunction with immunoglobulin quantitation. Utilizing an in-house developed software, retrospective quantitation and isotyping by Q-Mass-Fix of 6395 SPEP M-protein positive samples demonstrated good correlation with >90% of results not needing manual intervention. The assay was linear over a range of 7.5 to 0.004 g/dL with 75% of M-proteins detected at 0.004 g/dL. Thus, Q-Mass-Fix quantitation was superior to our current agarose gel SPEP and suitable for patient care.

Authors

Institutions

Publication Details

Journal
Journal of Immunological Methods
Published
2026-04-11
DOI
https://doi.org/10.1016/j.jim.2026.114052
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automated peak detection, isotyping and quantitation of M-proteins by MALDI-TOF MS for replacement of immunofixation and serum protein electrophoresis

Angela A. Dispenzieri, Patrick M. Vanderboom, Melissa R. Snyder, Maria Alice V. Willrich et al.
Journal of Immunological Methods
Mass Spectrometry Techniques and Applications
article

Automated peak detection, isotyping and quantitation of M-proteins by MALDI-TOF MS for replacement of immunofixation and serum protein electrophoresis

Angela A. Dispenzieri, Patrick M. Vanderboom, Melissa R. Snyder, Maria Alice V. Willrich, Mark Martinez, Mindy Kohlhagen, David Murray, Anne E. Tebo, Surendra Dasari, Jon D. Coker, James M. Larkin, Tax Kourelis
article en

Abstract

In 2018, the Mayo Clinic Protein Immunology Laboratory switched from immunofixation electrophoresis to a MALDI-TOF MS (Mass-Fix) method for the isotyping of M-proteins with a goal of replacing serum protein electrophoresis (SPEP) later. This study defines the performance characteristics of the MALDI-TOF MS method (Q-Mass-Fix) for simultaneous quantitation and isotyping of M-proteins in conjunction with immunoglobulin quantitation. Utilizing an in-house developed software, retrospective quantitation and isotyping by Q-Mass-Fix of 6395 SPEP M-protein positive samples demonstrated good correlation with >90% of results not needing manual intervention. The assay was linear over a range of 7.5 to 0.004 g/dL with 75% of M-proteins detected at 0.004 g/dL. Thus, Q-Mass-Fix quantitation was superior to our current agarose gel SPEP and suitable for patient care.

Journal of Immunological MethodsVol. 548
Mayo Clinic (US), Mayo Clinic in Arizona (US), Mayo Clinic in Florida (US)
Mayo Foundation for Medical Education and Research
Openalex Percentile: Top 25%
Mass Spectrometry Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Automated peak detection, isotyping and quantitation of M-proteins by MALDI-TOF MS for replacement of immunofixation and serum protein electrophoresis — Angela A. Dispenzieri, Patrick M. Vanderboom, et al. · Journal of Immunological Methods (2026) | TGRS Research Map | TGRS