Reactive Core Matting ( <scp>RCM</scp> ) to Passively Treat <scp>PFAS</scp> ‐Impacted Groundwater Discharging to a Small Stream

Abstract Groundwater near a former fire training area (FTA) discharges to a nearby small perennial stream and is impacted by per‐ and polyfluoroalkyl substances (PFAS), including (generally listed in order from highest to lowest concentrations): perfluorooctane sulfonate (PFOS), perfluorooctanoic acid (PFOA), perfluorohexanesulfonic acid (PFHxS), perfluorohexanoic acid (PFHxA), perfluorobutanesulfonic acid (PFBS), and perfluorobutanoic acid (PFBA). Upstream of the FTA, total PFAS (i.e., the sum of PFAS measured by United States Environmental Protection Agency [USEPA] Method 537.1, or Σ 24 PFAS) concentrations in the stream are about 10,000 ng/L resulting from various other PFAS sources, however, after passing by a 400‐feet long reach adjacent to the FTA, in‐stream Σ 24 PFAS concentration increase by an average of about 15,000 ng/L as a result of the discharge of impacted groundwater (the average Σ 24 PFAS mass discharge from groundwater is estimated at about 5.0 g/d. Reactive core matting (RCM) consisting of adsorptive media (FLUORO‐SORB ® 200) woven between two layers of permeable geo‐fabric was installed along a targeted reach of the stream to passively remove PFAS from discharging groundwater. Nine quarterly performance monitoring events, which included measurements of streamflow, and porewater and surface water concentrations, were conducted over a 2.4‐year performance period. The RCM was highly successful in reducing Σ 24 PFAS mass discharging from groundwater to the stream, removing an estimated 8.2 kg of Σ 24 PFAS, which represents nearly all PFAS mass discharging from groundwater. The stream treatment values (calculated from the increase in concentration over the reach after RCM installation compared to baseline) were relatively high and consistent, all averaging over 80%. However, some PFAS (notably PFBA, PFBS, PFHxA, and PFHxS) show a slight decline in stream treatment values for the last two monitoring events, possibly indicating treatment efficiency may have begun to decline for these specific PFAS. This work highlights both the practical implementability and efficacy of this technology, and therefore, RCMs are recommended for consideration at other similar PFAS‐impacted sites.

Authors

Publication Details

Journal
Groundwater Monitoring & Remediation
Published
2026-04-11
DOI
https://doi.org/10.1111/gwmr.70051
Primary Topic
Per- and polyfluoroalkyl substances research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reactive Core Matting ( RCM ) to Passively Treat PFAS ‐Impacted Groundwater Discharging to a Small Stream

Kim Heinze, Craig Divine, Jay C. Erickson, Allison Turner et al.
Groundwater Monitoring & Remediation
Per- and polyfluoroalkyl substances research
article

Reactive Core Matting ( RCM ) to Passively Treat PFAS ‐Impacted Groundwater Discharging to a Small Stream

Kim Heinze, Craig Divine, Jay C. Erickson, Allison Turner, Rita Krebs
article en

Abstract

Abstract Groundwater near a former fire training area (FTA) discharges to a nearby small perennial stream and is impacted by per‐ and polyfluoroalkyl substances (PFAS), including (generally listed in order from highest to lowest concentrations): perfluorooctane sulfonate (PFOS), perfluorooctanoic acid (PFOA), perfluorohexanesulfonic acid (PFHxS), perfluorohexanoic acid (PFHxA), perfluorobutanesulfonic acid (PFBS), and perfluorobutanoic acid (PFBA). Upstream of the FTA, total PFAS (i.e., the sum of PFAS measured by United States Environmental Protection Agency [USEPA] Method 537.1, or Σ 24 PFAS) concentrations in the stream are about 10,000 ng/L resulting from various other PFAS sources, however, after passing by a 400‐feet long reach adjacent to the FTA, in‐stream Σ 24 PFAS concentration increase by an average of about 15,000 ng/L as a result of the discharge of impacted groundwater (the average Σ 24 PFAS mass discharge from groundwater is estimated at about 5.0 g/d. Reactive core matting (RCM) consisting of adsorptive media (FLUORO‐SORB ® 200) woven between two layers of permeable geo‐fabric was installed along a targeted reach of the stream to passively remove PFAS from discharging groundwater. Nine quarterly performance monitoring events, which included measurements of streamflow, and porewater and surface water concentrations, were conducted over a 2.4‐year performance period. The RCM was highly successful in reducing Σ 24 PFAS mass discharging from groundwater to the stream, removing an estimated 8.2 kg of Σ 24 PFAS, which represents nearly all PFAS mass discharging from groundwater. The stream treatment values (calculated from the increase in concentration over the reach after RCM installation compared to baseline) were relatively high and consistent, all averaging over 80%. However, some PFAS (notably PFBA, PFBS, PFHxA, and PFHxS) show a slight decline in stream treatment values for the last two monitoring events, possibly indicating treatment efficiency may have begun to decline for these specific PFAS. This work highlights both the practical implementability and efficacy of this technology, and therefore, RCMs are recommended for consideration at other similar PFAS‐impacted sites.

Groundwater Monitoring & Remediation
Clean water and sanitation
Openalex Percentile: Top 17%
Per- and polyfluoroalkyl substances research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.