Ultra-high resolution photon-counting CT of the lung after lung transplantation: should we go for optimal image quality or reduced radiation dose?

Objectives: As an often-young population with regular CT follow-up, lung transplant (LTX) patients could benefit from both high spatial resolution and lower radiation dose. We compared the image quality of ultra-high-resolution photon-counting CT (UHR-PCCT) with high-resolution energy-integrating-detector CT (HR-EIDCT) at both a normal (IQ100) and a reduced radiation dose (IQ40) in patients after LTX. Methods: Hundred patients post-LTX, with an UHR-PCCT (0.4 mm) between Dec-2021 and Aug-2022, and prior HR-EIDCT (1.0 mm) <14 months apart, were included. In 49 patients, PCCT-IQ100 images were compared with previous HR-EIDCT; in 51 patients, PCCT-IQ40 images were compared with previous HR-EIDCT. Image quality was scored using a 5-point Liker scale (-2 to +2) for 7 relevant entities (peripheral airways, micronodules, reticulations, pleural thickening, consolidation, ground glass opacities (GGO), and air-trapping) plus an overall quality impression score. Results: < 0.0001). Conclusions: A significant dose reduction was achieved using the PCCT-IQ40 protocol. Although image quality was best in PCCT-IQ100, image quality in PCCT-IQ40 was non-inferior to EIDCT. Therefore, a significant radiation dose reduction is feasible without compromising image quality. Clinical relevance statement: PCCT offers improved image quality while reducing radiation dose significantly.For lung transplant patients, who are often younger and require lifelong, regular follow-up with CT, both improved image quality and lowered radiation dose would be very beneficial. Key Points: - LTX patients require long-term follow-up with high-resolution imaging to detect often subtle abnormalities and would benefit from both improved image quality and radiation dose reduction.- Perceived image quality was significantly higher in IQ100-PCCT than EIDCT; a significant further radiation dose reduction was feasible (IQ40-PCCT) without compromising image quality compared to EIDCT.

Authors

Institutions

Publication Details

Journal
JHLT Open
Published
2026-04-11
DOI
https://doi.org/10.1016/j.jhlto.2026.100547
Primary Topic
Transplantation: Methods and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultra-high resolution photon-counting CT of the lung after lung transplantation: should we go for optimal image quality or reduced radiation dose?

Adriana Dubbeldam, Kwinten Torfs, Emanuele Muscogiuri, Valerie Van Ballaer et al.
JHLT Open
Transplantation: Methods and Outcomes
article

Ultra-high resolution photon-counting CT of the lung after lung transplantation: should we go for optimal image quality or reduced radiation dose?

Adriana Dubbeldam, Kwinten Torfs, Emanuele Muscogiuri, Valerie Van Ballaer, Walter Coudyzer, Lesley Cockmartin, Hilde Bosmans, Emanuele Di Dedda, Walter De Wever, J. Coolen, Johny Verschakelen, Joke Binst
article en

Abstract

Objectives: As an often-young population with regular CT follow-up, lung transplant (LTX) patients could benefit from both high spatial resolution and lower radiation dose. We compared the image quality of ultra-high-resolution photon-counting CT (UHR-PCCT) with high-resolution energy-integrating-detector CT (HR-EIDCT) at both a normal (IQ100) and a reduced radiation dose (IQ40) in patients after LTX. Methods: Hundred patients post-LTX, with an UHR-PCCT (0.4 mm) between Dec-2021 and Aug-2022, and prior HR-EIDCT (1.0 mm) <14 months apart, were included. In 49 patients, PCCT-IQ100 images were compared with previous HR-EIDCT; in 51 patients, PCCT-IQ40 images were compared with previous HR-EIDCT. Image quality was scored using a 5-point Liker scale (-2 to +2) for 7 relevant entities (peripheral airways, micronodules, reticulations, pleural thickening, consolidation, ground glass opacities (GGO), and air-trapping) plus an overall quality impression score. Results: < 0.0001). Conclusions: A significant dose reduction was achieved using the PCCT-IQ40 protocol. Although image quality was best in PCCT-IQ100, image quality in PCCT-IQ40 was non-inferior to EIDCT. Therefore, a significant radiation dose reduction is feasible without compromising image quality. Clinical relevance statement: PCCT offers improved image quality while reducing radiation dose significantly.For lung transplant patients, who are often younger and require lifelong, regular follow-up with CT, both improved image quality and lowered radiation dose would be very beneficial. Key Points: - LTX patients require long-term follow-up with high-resolution imaging to detect often subtle abnormalities and would benefit from both improved image quality and radiation dose reduction.- Perceived image quality was significantly higher in IQ100-PCCT than EIDCT; a significant further radiation dose reduction was feasible (IQ40-PCCT) without compromising image quality compared to EIDCT.

JHLT OpenVol. 13
Rega Institute for Medical Research (BE), KU Leuven (BE)
Good health and well-being
Openalex Percentile: Top 32%
Transplantation: Methods and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.