Design of a fixture for precise perpendicular cuts in bone-implant sample preparation

Accurate specimen preparation is essential for biomechanical push-out testing of bone–implant interfaces. A common source of error arises when implants such as pins or screws are not cut exactly perpendicular to their axis. This results in oval or irregular cross-sections that compromise the validity of mechanical testing. In this study, we present a newly developed holder designed to ensure perpendicular sectioning of bone-anchored implants. Titanium pins coated with tricalcium phosphate (TCP) and GB14 were implanted in rabbit condyles and prepared for thin-section analysis using the Donath method. The roundness of implant cross-sections was quantitatively assessed with ImageJ (FIJI 1.53t) based on circularity and aspect ratio parameters. Compared with conventional freehand sectioning techniques, which exhibited a roundness of 0.83 ± 0.06 and an aspect ratio of 1.22 ± 0.09, the novel holder achieved markedly improved geometrical accuracy, with a roundness of 0.99 ± 0.002 and an aspect ratio of 1.003 ± 0.002. This difference was statistically significant (p < 0.01). These results demonstrate that the device effectively minimizes geometric artifacts during sample preparation, thereby enhancing reproducibility and reliability in subsequent biomechanical testing. Although the validation was limited to rabbit condyles, the holder is a simple and versatile instrument with the potential for application across different implant types and experimental models.

Authors

Institutions

Publication Details

Journal
BMC Research Notes
Published
2026-04-11
DOI
https://doi.org/10.1186/s13104-026-07813-7
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of a fixture for precise perpendicular cuts in bone-implant sample preparation

Bianca Riedel, Michael Seidenstuecker, Maria Carolina Lanzino, Mihail Genchev et al.
BMC Research Notes
Bone Tissue Engineering Materials
article

Design of a fixture for precise perpendicular cuts in bone-implant sample preparation

Bianca Riedel, Michael Seidenstuecker, Maria Carolina Lanzino, Mihail Genchev, Coralie Nagels, Hagen Schmal, Eva Johanna Kubosch
article en

Abstract

Accurate specimen preparation is essential for biomechanical push-out testing of bone–implant interfaces. A common source of error arises when implants such as pins or screws are not cut exactly perpendicular to their axis. This results in oval or irregular cross-sections that compromise the validity of mechanical testing. In this study, we present a newly developed holder designed to ensure perpendicular sectioning of bone-anchored implants. Titanium pins coated with tricalcium phosphate (TCP) and GB14 were implanted in rabbit condyles and prepared for thin-section analysis using the Donath method. The roundness of implant cross-sections was quantitatively assessed with ImageJ (FIJI 1.53t) based on circularity and aspect ratio parameters. Compared with conventional freehand sectioning techniques, which exhibited a roundness of 0.83 ± 0.06 and an aspect ratio of 1.22 ± 0.09, the novel holder achieved markedly improved geometrical accuracy, with a roundness of 0.99 ± 0.002 and an aspect ratio of 1.003 ± 0.002. This difference was statistically significant (p < 0.01). These results demonstrate that the device effectively minimizes geometric artifacts during sample preparation, thereby enhancing reproducibility and reliability in subsequent biomechanical testing. Although the validation was limited to rabbit condyles, the holder is a simple and versatile instrument with the potential for application across different implant types and experimental models.

BMC Research NotesVol. 19(1)
University of Stuttgart (DE), University of Freiburg (DE), University Medical Center Freiburg (DE), Odense University Hospital (DK), Stuttgart Technical University of Applied Sciences (DE)
Deutsche Forschungsgemeinschaft, Albert-Ludwigs-Universität Freiburg
Openalex Percentile: Top 31%
Bone Tissue Engineering Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.