From bench to bedside: a novel suture-augmented prosthesis for greater trochanteric fixation in osteoporotic hip arthroplasty

BACKGROUND: Stable fixation of the greater trochanter during hip arthroplasty for unstable osteoporotic intertrochanteric fractures remains a significant challenge. Conventional techniques depend on securing the bone-implant interface, which is particularly compromised in osteoporotic bone. Here, we propose a novel conceptual approach that establishes a direct mechanical bridge from the abductor tendon to the prosthesis, thereby reducing reliance on the fragile bone-implant interface. METHODS: In this two-stage translational study, we progressed from biomechanical validation to clinical application. First, using a decalcified caprine femoral model simulating osteoporosis, three fixation constructs were compared: locking plate (LP), suture-augmented locking plate (LPSA), and Kirschner-wire tension band (KWTB). Ultimate load and construct stability were evaluated. Biomechanical testing confirmed the principle of suture-mediated load sharing and highlighted the intrinsic weakness of screw fixation in osteoporotic bone. Guided by these results, we designed a novel femoral prosthesis that eliminates screw fixation, employs sutures as the primary load-bearing element, and incorporates integrated suture anchor tunnels. This prosthesis was then assessed in a retrospective series of 15 consecutive elderly patients with osteoporotic intertrochanteric fractures. Clinical outcomes were evaluated using the Harris Hip Score (HHS). RESULTS: Biomechanically, the LPSA construct sustained a significantly higher ultimate load than the LP construct in decalcified bone (P < 0.001) and exhibited a greater load at 2-mm displacement than the KWTB construct (P < 0.001). Clinically, all patients achieved fracture union without prosthesis-related complications. The mean HHS at final follow-up was 88.27 ± 6.60, and 80% of patients regained independent ambulation. CONCLUSIONS: A prosthesis-anchored, suture-mediated "tendon-to-prosthesis" load pathway provides reliable stabilization of the greater trochanter in osteoporotic bone. Biomechanical validation and favorable early clinical outcomes support the potential of this novel fixation strategy.

Authors

Institutions

Publication Details

Journal
Journal of Orthopaedics and Traumatology
Published
2026-04-11
DOI
https://doi.org/10.1186/s10195-026-00919-5
Primary Topic
Hip and Femur Fractures
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

From bench to bedside: a novel suture-augmented prosthesis for greater trochanteric fixation in osteoporotic hip arthroplasty

Faxue Liao, Kunpeng Qin, Chao Zhang, Rui Sheng et al.
Journal of Orthopaedics and Traumatology
Hip and Femur Fractures
article

From bench to bedside: a novel suture-augmented prosthesis for greater trochanteric fixation in osteoporotic hip arthroplasty

Faxue Liao, Kunpeng Qin, Chao Zhang, Rui Sheng, Junjun Yang, Guangwen Ma, Jun Chang, Zhangwei Wu, Sijie Bian, Xu Wang, Congying Xie, Xiaoqin Ding, Huaiping Yuan
article en

Abstract

BACKGROUND: Stable fixation of the greater trochanter during hip arthroplasty for unstable osteoporotic intertrochanteric fractures remains a significant challenge. Conventional techniques depend on securing the bone-implant interface, which is particularly compromised in osteoporotic bone. Here, we propose a novel conceptual approach that establishes a direct mechanical bridge from the abductor tendon to the prosthesis, thereby reducing reliance on the fragile bone-implant interface. METHODS: In this two-stage translational study, we progressed from biomechanical validation to clinical application. First, using a decalcified caprine femoral model simulating osteoporosis, three fixation constructs were compared: locking plate (LP), suture-augmented locking plate (LPSA), and Kirschner-wire tension band (KWTB). Ultimate load and construct stability were evaluated. Biomechanical testing confirmed the principle of suture-mediated load sharing and highlighted the intrinsic weakness of screw fixation in osteoporotic bone. Guided by these results, we designed a novel femoral prosthesis that eliminates screw fixation, employs sutures as the primary load-bearing element, and incorporates integrated suture anchor tunnels. This prosthesis was then assessed in a retrospective series of 15 consecutive elderly patients with osteoporotic intertrochanteric fractures. Clinical outcomes were evaluated using the Harris Hip Score (HHS). RESULTS: Biomechanically, the LPSA construct sustained a significantly higher ultimate load than the LP construct in decalcified bone (P < 0.001) and exhibited a greater load at 2-mm displacement than the KWTB construct (P < 0.001). Clinically, all patients achieved fracture union without prosthesis-related complications. The mean HHS at final follow-up was 88.27 ± 6.60, and 80% of patients regained independent ambulation. CONCLUSIONS: A prosthesis-anchored, suture-mediated "tendon-to-prosthesis" load pathway provides reliable stabilization of the greater trochanter in osteoporotic bone. Biomechanical validation and favorable early clinical outcomes support the potential of this novel fixation strategy.

Journal of Orthopaedics and Traumatology
Anhui Medical University (CN), Anhui Provincial Hospital (CN), First Affiliated Hospital of Anhui Medical University (CN), Anhui Mental Health Center (CN)
Openalex Percentile: Top 22%
Hip and Femur Fractures
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.