From bench to bedside: a novel suture-augmented prosthesis for greater trochanteric fixation in osteoporotic hip arthroplasty
BACKGROUND: Stable fixation of the greater trochanter during hip arthroplasty for unstable osteoporotic intertrochanteric fractures remains a significant challenge. Conventional techniques depend on securing the bone-implant interface, which is particularly compromised in osteoporotic bone. Here, we propose a novel conceptual approach that establishes a direct mechanical bridge from the abductor tendon to the prosthesis, thereby reducing reliance on the fragile bone-implant interface. METHODS: In this two-stage translational study, we progressed from biomechanical validation to clinical application. First, using a decalcified caprine femoral model simulating osteoporosis, three fixation constructs were compared: locking plate (LP), suture-augmented locking plate (LPSA), and Kirschner-wire tension band (KWTB). Ultimate load and construct stability were evaluated. Biomechanical testing confirmed the principle of suture-mediated load sharing and highlighted the intrinsic weakness of screw fixation in osteoporotic bone. Guided by these results, we designed a novel femoral prosthesis that eliminates screw fixation, employs sutures as the primary load-bearing element, and incorporates integrated suture anchor tunnels. This prosthesis was then assessed in a retrospective series of 15 consecutive elderly patients with osteoporotic intertrochanteric fractures. Clinical outcomes were evaluated using the Harris Hip Score (HHS). RESULTS: Biomechanically, the LPSA construct sustained a significantly higher ultimate load than the LP construct in decalcified bone (P < 0.001) and exhibited a greater load at 2-mm displacement than the KWTB construct (P < 0.001). Clinically, all patients achieved fracture union without prosthesis-related complications. The mean HHS at final follow-up was 88.27 ± 6.60, and 80% of patients regained independent ambulation. CONCLUSIONS: A prosthesis-anchored, suture-mediated "tendon-to-prosthesis" load pathway provides reliable stabilization of the greater trochanter in osteoporotic bone. Biomechanical validation and favorable early clinical outcomes support the potential of this novel fixation strategy.
Authors
- Faxue Liao (ORCID: https://orcid.org/0009-0006-9667-895X)
- Kunpeng Qin
- Chao Zhang (ORCID: https://orcid.org/0000-0003-0399-1201)
- Rui Sheng (ORCID: https://orcid.org/0000-0002-7418-2850)
- Junjun Yang
- Guangwen Ma
- Jun Chang
- Zhangwei Wu
- Sijie Bian
- Xu Wang
- Congying Xie
- Xiaoqin Ding
- Huaiping Yuan
Institutions
- Anhui Medical University (CN)
- Anhui Provincial Hospital (CN)
- First Affiliated Hospital of Anhui Medical University (CN)
- Anhui Mental Health Center (CN)
Publication Details
- Journal
- Journal of Orthopaedics and Traumatology
- Published
- 2026-04-11
- DOI
- https://doi.org/10.1186/s10195-026-00919-5
- Primary Topic
- Hip and Femur Fractures
- Type
- article
- Field-Weighted Citation Impact
- 0.00